433844000: Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure)


    Status: retired, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 01-May 2024. Module: SNOMED CT core

    Descriptions:

    Id Description Lang Type Status Case? Module
    2745797015 Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
    2767439014 Insertion of cardiac biventricular implantable cardioverter defibrillator (ICD) using fluoroscopic guidance en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core
    2767440011 Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
    2773768011 Fluoroscopic guidance for insertion of cardiac biventricular ICD en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core


    0 descendants.

    Expanded Value Set


    Outbound Relationships Type Target Active Characteristic Refinability Group Values
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Is a Insertion of cardiac defibrillator using fluoroscopic guidance (procedure) false Inferred relationship Some
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Method Insertion - action (qualifier value) false Inferred relationship Some 1
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Has intent Guidance intent (qualifier value) false Inferred relationship Some 1
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Method Fluoroscopic imaging - action (qualifier value) false Inferred relationship Some 1
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Direct device Automatic cardiac defibrillator false Inferred relationship Some 1
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Procedure site - Direct (attribute) Heart structure false Inferred relationship Some 1
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Procedure site - Indirect (attribute) Heart structure false Inferred relationship Some 1
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Method Insertion - action (qualifier value) false Inferred relationship Some 2
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Direct device Automatic cardiac defibrillator false Inferred relationship Some 1
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Procedure site - Direct (attribute) Heart structure false Inferred relationship Some 1
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Has intent Guidance intent (qualifier value) false Inferred relationship Some 1
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Method Fluoroscopic imaging - action (qualifier value) false Inferred relationship Some 1
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Procedure site - Indirect (attribute) Heart structure false Inferred relationship Some 2
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Is a Insertion of biventricular implantable cardioverter defibrillator false Inferred relationship Some
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Method Insertion - action (qualifier value) false Inferred relationship Some 2
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Direct device Implantable defibrillator false Inferred relationship Some 2
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Procedure site - Indirect (attribute) Heart structure false Inferred relationship Some 2
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Direct device Implantable defibrillator false Inferred relationship Some 2
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Direct device Implantable defibrillator false Inferred relationship Some 1
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Method Fluoroscopic imaging - action (qualifier value) false Inferred relationship Some 2
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Has intent Guidance intent (qualifier value) false Inferred relationship Some 2
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Method Implantation - action false Inferred relationship Some 3
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Procedure site - Indirect (attribute) Heart structure false Inferred relationship Some 3
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Direct device Implantable defibrillator false Inferred relationship Some 3
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Is a Insertion using fluoroscopic guidance (procedure) false Inferred relationship Some
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Is a Cardiovascular investigation false Inferred relationship Some
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Procedure site - Direct (attribute) Heart structure false Inferred relationship Some 2
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Is a Fluoroscopic guidance false Inferred relationship Some
    Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Is a Cardiac fluoroscopy false Inferred relationship Some

    Inbound Relationships Type Active Source Characteristic Refinability Group

    Reference Sets

    Concept inactivation indicator reference set

    SAME AS association reference set (foundation metadata concept)

    Back to Start