FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

281952008: Fixation of fracture using dynamic compression system (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
420120010 Fixation of fracture using dynamic compression system en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
675550017 Fixation of fracture using dynamic compression system (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Fixation of fracture using dynamic compression system Is a Internal fixation of fracture true Inferred relationship Some
Fixation of fracture using dynamic compression system Is a Introduction procedure (procedure) false Inferred relationship Some
Fixation of fracture using dynamic compression system Procedure site Bone structure false Inferred relationship Some 1
Fixation of fracture using dynamic compression system Method Fixation - action false Inferred relationship Some 1
Fixation of fracture using dynamic compression system Method Implantation - action false Inferred relationship Some 2
Fixation of fracture using dynamic compression system Procedure site Skeletal system structure false Inferred relationship Some
Fixation of fracture using dynamic compression system Access Open approach false Inferred relationship Some
Fixation of fracture using dynamic compression system Is a Musculoskeletal system implantation false Inferred relationship Some
Fixation of fracture using dynamic compression system Direct morphology Fracture false Inferred relationship Some 1
Fixation of fracture using dynamic compression system Direct device Orthopedic internal fixation system false Inferred relationship Some
Fixation of fracture using dynamic compression system Using Orthopedic internal fixation system false Inferred relationship Some 1
Fixation of fracture using dynamic compression system Procedure site - Indirect (attribute) Bone structure false Inferred relationship Some 1
Fixation of fracture using dynamic compression system Direct device Orthopedic internal fixation system false Inferred relationship Some 1
Fixation of fracture using dynamic compression system Procedure site - Direct (attribute) Bone structure false Inferred relationship Some 1
Fixation of fracture using dynamic compression system Using device (attribute) Orthopedic internal fixation system false Inferred relationship Some 1
Fixation of fracture using dynamic compression system Direct morphology Fracture true Inferred relationship Some 1
Fixation of fracture using dynamic compression system Using device (attribute) Orthopedic internal fixation system true Inferred relationship Some 1
Fixation of fracture using dynamic compression system Method Fixation - action true Inferred relationship Some 1
Fixation of fracture using dynamic compression system Procedure site - Direct (attribute) Bone structure true Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Is a False Fixation of fracture using dynamic compression system Inferred relationship Some

Reference Sets

GB English

US English

Back to Start