Status: retired, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 01-Aug 2024. Module: SNOMED CT core
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
731340019 | Mechanical complication due to cardiac pacemaker electrode (disorder) | en | Fully specified name | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
2664239017 | Mechanical complication due to cardiac pacemaker electrode | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Mechanical complication due to cardiac pacemaker electrode | Is a | Mechanical complication of cardiac device, implant AND/OR graft | false | Inferred relationship | Some | ||
Mechanical complication due to cardiac pacemaker electrode | Causative agent | Cardiac pacemaker | false | Inferred relationship | Some | ||
Mechanical complication due to cardiac pacemaker electrode | Causative agent | Electrode | false | Inferred relationship | Some | ||
Mechanical complication due to cardiac pacemaker electrode | Temporally follows | Surgical procedure | false | Inferred relationship | Some | ||
Mechanical complication due to cardiac pacemaker electrode | Temporally follows | Cardiac pacemaker procedure | false | Inferred relationship | Some | ||
Mechanical complication due to cardiac pacemaker electrode | Temporally follows | Surgical procedure (procedure) | false | Inferred relationship | Some | ||
Mechanical complication due to cardiac pacemaker electrode | After | Cardiac pacemaker procedure | false | Inferred relationship | Some | 1 | |
Mechanical complication due to cardiac pacemaker electrode | After | Surgical procedure (procedure) | false | Inferred relationship | Some | ||
Mechanical complication due to cardiac pacemaker electrode | Associated with | Surgical procedure (procedure) | false | Inferred relationship | Some | ||
Mechanical complication due to cardiac pacemaker electrode | Is a | Disorder following clinical procedure | false | Inferred relationship | Some | ||
Mechanical complication due to cardiac pacemaker electrode | Associated with | Cardiac pacemaker electrode | false | Inferred relationship | Some | 2 | |
Mechanical complication due to cardiac pacemaker electrode | Is a | Mechanical complication of cardiac implant | false | Inferred relationship | Some | ||
Mechanical complication due to cardiac pacemaker electrode | Is a | Mechanical complication of device | false | Inferred relationship | Some | ||
Mechanical complication due to cardiac pacemaker electrode | Is a | Mechanical complication of implant | false | Inferred relationship | Some | ||
Mechanical complication due to cardiac pacemaker electrode | Is a | Mechanical complication of cardiovascular device | false | Inferred relationship | Some |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
Disorder of cardiac pacemaker electrode | Is a | False | Mechanical complication due to cardiac pacemaker electrode | Inferred relationship | Some | |
Pacemaker electrode displacement | Is a | False | Mechanical complication due to cardiac pacemaker electrode | Inferred relationship | Some |
Reference Sets
Concept inactivation indicator reference set
REPLACED BY association reference set (foundation metadata concept)