FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

271983002: Disorder of cardiac pacemaker system (disorder)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
407015019 Disorder of cardiac pacemaker system en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
664455017 Disorder of cardiac pacemaker system (disorder) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core


35 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Disorder of cardiac pacemaker system Is a Disorder of cardiovascular prostheses and implants false Inferred relationship Some
Disorder of cardiac pacemaker system Is a Mechanical complication of cardiac device, implant AND/OR graft false Inferred relationship Some
Disorder of cardiac pacemaker system Is a Heart disease false Inferred relationship Some
Disorder of cardiac pacemaker system Temporally follows Procedure false Inferred relationship Some
Disorder of cardiac pacemaker system Finding site Cardiac structure false Inferred relationship Some
Disorder of cardiac pacemaker system Temporally follows Surgical procedure false Inferred relationship Some
Disorder of cardiac pacemaker system Is a Disorder of thorax (disorder) false Inferred relationship Some
Disorder of cardiac pacemaker system Temporally follows Surgical procedure (procedure) false Inferred relationship Some
Disorder of cardiac pacemaker system Temporally follows Implantation false Inferred relationship Some
Disorder of cardiac pacemaker system Is a Heart disease false Inferred relationship Some
Disorder of cardiac pacemaker system Finding site Cardiovascular system subdivision false Inferred relationship Some
Disorder of cardiac pacemaker system After Implantation of prosthetic device false Inferred relationship Some
Disorder of cardiac pacemaker system Finding site Structure of cardiovascular system (body structure) false Inferred relationship Some
Disorder of cardiac pacemaker system After Surgical procedure (procedure) false Inferred relationship Some
Disorder of cardiac pacemaker system Associated with Surgical procedure (procedure) false Inferred relationship Some
Disorder of cardiac pacemaker system Associated with Cardiac pacemaker true Inferred relationship Some 1
Disorder of cardiac pacemaker system Associated with Procedure false Inferred relationship Some
Disorder of cardiac pacemaker system Is a Complication associated with cardiac implant false Inferred relationship Some
Disorder of cardiac pacemaker system Due to Procedure false Inferred relationship Some 2
Disorder of cardiac pacemaker system Associated with Implant false Inferred relationship Some 3
Disorder of cardiac pacemaker system Is a Complication associated with device (disorder) true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group
Disorder of cardiac pacemaker electrode Is a True Disorder of cardiac pacemaker system Inferred relationship Some
Disorder of pacemaker pulse generator Is a False Disorder of cardiac pacemaker system Inferred relationship Some
Infected pacemaker Is a True Disorder of cardiac pacemaker system Inferred relationship Some
Disorder of pacing function Is a True Disorder of cardiac pacemaker system Inferred relationship Some
Mechanical complication of cardiac pacemaker Is a True Disorder of cardiac pacemaker system Inferred relationship Some
Cardiac arrest due to pacemaker failure Is a False Disorder of cardiac pacemaker system Inferred relationship Some
Malfunction of cardiac pacemaker (disorder) Is a False Disorder of cardiac pacemaker system Inferred relationship Some
Complication associated with cardiac pacemaker lead (disorder) Is a True Disorder of cardiac pacemaker system Inferred relationship Some
Erosion of pacemaker pocket due to and following implantation of cardiac pacemaker (disorder) Is a False Disorder of cardiac pacemaker system Inferred relationship Some
Stimulation of muscle pocket due to and after implantation of cardiac pacemaker (disorder) Is a True Disorder of cardiac pacemaker system Inferred relationship Some
Stimulation of phrenic nerve due to and after implantation of cardiac pacemaker (disorder) Is a True Disorder of cardiac pacemaker system Inferred relationship Some
Cardiac arrest due to pacemaker failure Due to True Disorder of cardiac pacemaker system Inferred relationship Some 2

This concept is not in any reference sets

Back to Start