1153380009: Mechanical hemolysis following insertion of prosthetic heart valve (disorder)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2021. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
4564168019 Mechanical haemolysis due to prosthetic valve en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
4564169010 Mechanical hemolysis following insertion of prosthetic heart valve (disorder) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
4564170011 Mechanical hemolysis following insertion of prosthetic heart valve en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
5248009013 Mechanical haemolysis following insertion of prosthetic heart valve en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Mechanical hemolysis following insertion of prosthetic heart valve (disorder) Interprets Red blood cell count true Inferred relationship Some 2
Mechanical hemolysis following insertion of prosthetic heart valve (disorder) Has interpretation Below reference range true Inferred relationship Some 4
Mechanical hemolysis following insertion of prosthetic heart valve (disorder) Has interpretation Present true Inferred relationship Some 3
Mechanical hemolysis following insertion of prosthetic heart valve (disorder) Interprets Hemolysis (observable entity) true Inferred relationship Some 3
Mechanical hemolysis following insertion of prosthetic heart valve (disorder) Is a Traumatic cardiac hemolytic anemia true Inferred relationship Some
Mechanical hemolysis following insertion of prosthetic heart valve (disorder) Has interpretation Below reference range true Inferred relationship Some 2
Mechanical hemolysis following insertion of prosthetic heart valve (disorder) Finding site Erythrocyte true Inferred relationship Some 5
Mechanical hemolysis following insertion of prosthetic heart valve (disorder) Is a Postoperative complication (disorder) true Inferred relationship Some
Mechanical hemolysis following insertion of prosthetic heart valve (disorder) Interprets Measurement of total haemoglobin concentration true Inferred relationship Some 4
Mechanical hemolysis following insertion of prosthetic heart valve (disorder) After Prosthetic replacement of heart valve false Inferred relationship Some 1
Mechanical hemolysis following insertion of prosthetic heart valve (disorder) Is a Hemoglobin below reference range (finding) true Inferred relationship Some
Mechanical hemolysis following insertion of prosthetic heart valve (disorder) Is a Red blood cell disorder true Inferred relationship Some
Mechanical hemolysis following insertion of prosthetic heart valve (disorder) After Heart valve replacement true Inferred relationship Some 1
Mechanical hemolysis following insertion of prosthetic heart valve (disorder) Is a Complication of introduction procedure true Inferred relationship Some
Mechanical hemolysis following insertion of prosthetic heart valve (disorder) Is a Hematologic complication of procedure true Inferred relationship Some
Mechanical hemolysis following insertion of prosthetic heart valve (disorder) Is a Complication of surgical procedure true Inferred relationship Some
Mechanical hemolysis following insertion of prosthetic heart valve (disorder) Due to Heart valve replacement true Inferred relationship Some 6

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start