FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

900061000000109: Measurement of concentration of darunavir in serum specimen (procedure)


Status: current, Sufficiently defined by necessary conditions definition status. Date: 05-Aug 2020. Module: SNOMED CT United Kingdom clinical extension module

Descriptions:

Id Description Lang Type Status Case? Module
2315221000000114 Measurement of concentration of darunavir in serum specimen (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT United Kingdom clinical extension module
2315231000000111 Serum darunavir concentration measurement en Synonym Active Entire term case insensitive SNOMED CT United Kingdom clinical extension module
2315261000000118 Serum darunavir concentration en Synonym Active Entire term case insensitive SNOMED CT United Kingdom clinical extension module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Measurement of concentration of darunavir in serum specimen (procedure) Component Darunavir false Inferred relationship Existential restriction modifier
Measurement of concentration of darunavir in serum specimen (procedure) Is a Measurement of darunavir (procedure) true Inferred relationship Existential restriction modifier
Measurement of concentration of darunavir in serum specimen (procedure) Is a Measurement of level of substance in blood true Inferred relationship Existential restriction modifier
Measurement of concentration of darunavir in serum specimen (procedure) Method Measurement - action true Inferred relationship Existential restriction modifier 1
Measurement of concentration of darunavir in serum specimen (procedure) Has specimen Serum specimen true Inferred relationship Existential restriction modifier 2
Measurement of concentration of darunavir in serum specimen (procedure) Component Darunavir true Inferred relationship Existential restriction modifier 3
Measurement of concentration of darunavir in serum specimen (procedure) Is a Measurement of darunavir (procedure) false Inferred relationship Existential restriction modifier
Measurement of concentration of darunavir in serum specimen (procedure) PBCL flag true PBCL flag true: report, request, level, test false Additional relationship Existential restriction modifier
Measurement of concentration of darunavir in serum specimen (procedure) Component Darunavir false Inferred relationship Existential restriction modifier
Measurement of concentration of darunavir in serum specimen (procedure) Method Measurement - action false Inferred relationship Existential restriction modifier

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start