FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

854951000000102: Insertion of biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status. Date: 01-Oct 2012. Module: SNOMED CT United Kingdom clinical extension module

Descriptions:

Id Description Lang Type Status Case? Module
2213561000000114 Fluoroscopy guided insertion of biventricular implantable cardioverter defibrillator lead en Synonym Active Entire term case insensitive SNOMED CT United Kingdom clinical extension module
2213571000000119 Insertion of biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT United Kingdom clinical extension module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Insertion of biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Is a Heart implantation false Inferred relationship Existential restriction modifier
Insertion of biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Is a Cardiac fluoroscopy true Inferred relationship Existential restriction modifier
Insertion of biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Is a Cardiac pacemaker procedure using fluoroscopic guidance true Inferred relationship Existential restriction modifier
Insertion of biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Is a Cardiac pacemaker procedure false Inferred relationship Existential restriction modifier
Insertion of biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Is a Insertion of therapeutic device false Inferred relationship Existential restriction modifier
Insertion of biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Direct device Implantable cardioverter leads, device true Inferred relationship Existential restriction modifier 1
Insertion of biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Is a Biomedical equipment procedure true Inferred relationship Existential restriction modifier
Insertion of biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Is a Insertion using fluoroscopic guidance true Inferred relationship Existential restriction modifier
Insertion of biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Procedure site - Direct Heart structure true Inferred relationship Existential restriction modifier 2
Insertion of biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Method Insertion - action true Inferred relationship Existential restriction modifier 1
Insertion of biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Procedure site - Indirect Heart structure true Inferred relationship Existential restriction modifier 1
Insertion of biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Method Fluoroscopic imaging - action true Inferred relationship Existential restriction modifier 2
Insertion of biventricular implantable cardioverter defibrillator lead using fluoroscopic guidance (procedure) Has intent Guidance intent true Inferred relationship Existential restriction modifier 2

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start