FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.24  |  FHIR Version n/a  User: [n/a]

76024009: Internal fixation of scapula without fracture reduction (procedure)


Status: current, Sufficiently defined by necessary conditions definition status. Date: 31-Jan 2014. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
126279014 Internal fixation of scapula without fracture reduction en Synonym Active Entire term case insensitive SNOMED CT core module
816699016 Internal fixation of scapula without fracture reduction (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT core module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Internal fixation of scapula without fracture reduction Is a Internal fixation of bone without fracture reduction true Inferred relationship Existential restriction modifier
Internal fixation of scapula without fracture reduction Is a Internal fixation of scapula true Inferred relationship Existential restriction modifier
Internal fixation of scapula without fracture reduction Access Open approach - access false Inferred relationship Existential restriction modifier
Internal fixation of scapula without fracture reduction Procedure site Bone structure of scapula false Inferred relationship Existential restriction modifier 2
Internal fixation of scapula without fracture reduction Using Orthopedic internal fixation system, device false Inferred relationship Existential restriction modifier
Internal fixation of scapula without fracture reduction Method Fixation - action false Inferred relationship Existential restriction modifier 1
Internal fixation of scapula without fracture reduction Direct device Orthopedic internal fixation system, device false Inferred relationship Existential restriction modifier 1
Internal fixation of scapula without fracture reduction Using Orthopedic internal fixation system, device false Inferred relationship Existential restriction modifier 1
Internal fixation of scapula without fracture reduction Method Fixation - action false Inferred relationship Existential restriction modifier 2
Internal fixation of scapula without fracture reduction Procedure site Bone structure false Inferred relationship Existential restriction modifier 1
Internal fixation of scapula without fracture reduction Method Fixation - action false Inferred relationship Existential restriction modifier 1
Internal fixation of scapula without fracture reduction Method Fixation - action false Inferred relationship Existential restriction modifier 2
Internal fixation of scapula without fracture reduction Direct morphology Fracture false Inferred relationship Existential restriction modifier 1
Internal fixation of scapula without fracture reduction Procedure site - Indirect Bone structure false Inferred relationship Existential restriction modifier 1
Internal fixation of scapula without fracture reduction Method Fixation - action false Inferred relationship Existential restriction modifier 1
Internal fixation of scapula without fracture reduction Method Fixation - action false Inferred relationship Existential restriction modifier 2
Internal fixation of scapula without fracture reduction Method Fixation - action false Inferred relationship Existential restriction modifier 1
Internal fixation of scapula without fracture reduction Method Fixation - action false Inferred relationship Existential restriction modifier 2
Internal fixation of scapula without fracture reduction Method Fixation - action false Inferred relationship Existential restriction modifier 1
Internal fixation of scapula without fracture reduction Method Fixation - action false Inferred relationship Existential restriction modifier 2
Internal fixation of scapula without fracture reduction Procedure site - Direct Bone structure false Inferred relationship Existential restriction modifier 1
Internal fixation of scapula without fracture reduction Using device Orthopedic internal fixation system, device false Inferred relationship Existential restriction modifier 1
Internal fixation of scapula without fracture reduction Procedure site - Direct Bone structure of scapula false Inferred relationship Existential restriction modifier 1
Internal fixation of scapula without fracture reduction Method Fixation - action false Inferred relationship Existential restriction modifier 1
Internal fixation of scapula without fracture reduction Method Fixation - action false Inferred relationship Existential restriction modifier 1
Internal fixation of scapula without fracture reduction Using device Orthopedic internal fixation system, device true Inferred relationship Existential restriction modifier 1
Internal fixation of scapula without fracture reduction Method Fixation - action true Inferred relationship Existential restriction modifier 1
Internal fixation of scapula without fracture reduction Procedure site - Direct Bone structure of scapula true Inferred relationship Existential restriction modifier 1
Internal fixation of scapula without fracture reduction Is a Operative procedure on region of shoulder girdle false Inferred relationship Existential restriction modifier
Internal fixation of scapula without fracture reduction Is a Operative procedure on bone of upper extremity false Inferred relationship Existential restriction modifier
Internal fixation of scapula without fracture reduction Is a Surgical procedure on thorax false Inferred relationship Existential restriction modifier

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start