Status: current, Sufficiently defined by necessary conditions definition status. Date: 31-Jan 2018. Module: SNOMED CT core module
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
3513037016 | Closed reduction of fracture of left femur and internal fixation using dynamic hip screw plate (procedure) | en | Fully specified name | Active | Entire term case insensitive | SNOMED CT core module |
3513038014 | Closed reduction and dynamic hip screw of fracture of left femur | en | Synonym | Active | Entire term case insensitive | SNOMED CT core module |
3513039018 | Closed reduction of fracture of left femur and internal fixation using dynamic hip screw plate | en | Synonym | Active | Entire term case insensitive | SNOMED CT core module |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Closed reduction of fracture of left femur and internal fixation using dynamic hip screw plate | Is a | Closed reduction of fracture of femur and internal fixation using dynamic hip screw plate | true | Inferred relationship | Existential restriction modifier | ||
Closed reduction of fracture of left femur and internal fixation using dynamic hip screw plate | Method | Fixation - action | true | Inferred relationship | Existential restriction modifier | 2 | |
Closed reduction of fracture of left femur and internal fixation using dynamic hip screw plate | Direct morphology | Fracture | true | Inferred relationship | Existential restriction modifier | 2 | |
Closed reduction of fracture of left femur and internal fixation using dynamic hip screw plate | Procedure site - Direct | Structure of bone of left femur | true | Inferred relationship | Existential restriction modifier | 2 | |
Closed reduction of fracture of left femur and internal fixation using dynamic hip screw plate | Using device | Dynamic hip screw plate | true | Inferred relationship | Existential restriction modifier | 2 | |
Closed reduction of fracture of left femur and internal fixation using dynamic hip screw plate | Method | Closed reduction - action | true | Inferred relationship | Existential restriction modifier | 3 | |
Closed reduction of fracture of left femur and internal fixation using dynamic hip screw plate | Direct morphology | Fracture | true | Inferred relationship | Existential restriction modifier | 3 | |
Closed reduction of fracture of left femur and internal fixation using dynamic hip screw plate | Procedure site - Direct | Structure of bone of left femur | true | Inferred relationship | Existential restriction modifier | 3 |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
This concept is not in any reference sets