FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

60515004: Muscle-testing electrodiagnosis with chronaximetry (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status. Date: 31-Jan 2002. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
100545011 Muscle-testing electrodiagnosis with chronaximetry en Synonym Active Entire term case insensitive SNOMED CT core module
799476015 Muscle-testing electrodiagnosis with chronaximetry (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT core module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Muscle-testing electrodiagnosis with chronaximetry Is a Electrical muscle-testing true Inferred relationship Existential restriction modifier
Muscle-testing electrodiagnosis with chronaximetry Has intent Therapeutic intent false Inferred relationship Existential restriction modifier
Muscle-testing electrodiagnosis with chronaximetry Procedure site Skeletal muscle system structure false Inferred relationship Existential restriction modifier 2
Muscle-testing electrodiagnosis with chronaximetry Method Investigation - action false Inferred relationship Existential restriction modifier
Muscle-testing electrodiagnosis with chronaximetry Has intent Diagnostic intent false Inferred relationship Existential restriction modifier 2
Muscle-testing electrodiagnosis with chronaximetry Procedure site Structure of nervous system false Inferred relationship Existential restriction modifier
Muscle-testing electrodiagnosis with chronaximetry Using Stimulator, device false Inferred relationship Existential restriction modifier
Muscle-testing electrodiagnosis with chronaximetry Procedure site Skeletal and/or smooth muscle structure false Inferred relationship Existential restriction modifier 1
Muscle-testing electrodiagnosis with chronaximetry Is a Procedure categorized by device involved false Inferred relationship Existential restriction modifier
Muscle-testing electrodiagnosis with chronaximetry Method Evaluation - action false Inferred relationship Existential restriction modifier 1
Muscle-testing electrodiagnosis with chronaximetry Direct device Stimulator, device false Inferred relationship Existential restriction modifier
Muscle-testing electrodiagnosis with chronaximetry Using Stimulator, device false Inferred relationship Existential restriction modifier
Muscle-testing electrodiagnosis with chronaximetry Method Evaluation - action false Inferred relationship Existential restriction modifier 2
Muscle-testing electrodiagnosis with chronaximetry Is a Procedure categorized by device involved false Inferred relationship Existential restriction modifier
Muscle-testing electrodiagnosis with chronaximetry Method Evaluation - action false Inferred relationship Existential restriction modifier 1
Muscle-testing electrodiagnosis with chronaximetry Method Evaluation - action false Inferred relationship Existential restriction modifier 2
Muscle-testing electrodiagnosis with chronaximetry Method Functional assessment - action false Inferred relationship Existential restriction modifier 2
Muscle-testing electrodiagnosis with chronaximetry Method Evaluation - action false Inferred relationship Existential restriction modifier 1
Muscle-testing electrodiagnosis with chronaximetry Method Evaluation - action false Inferred relationship Existential restriction modifier 1
Muscle-testing electrodiagnosis with chronaximetry Procedure site Skeletal muscle structure false Inferred relationship Existential restriction modifier 1
Muscle-testing electrodiagnosis with chronaximetry Using device Stimulator, device false Inferred relationship Existential restriction modifier 1
Muscle-testing electrodiagnosis with chronaximetry Procedure site - Direct Skeletal muscle structure false Inferred relationship Existential restriction modifier 1
Muscle-testing electrodiagnosis with chronaximetry Procedure site Structure of nervous system true Inferred relationship Existential restriction modifier 3
Muscle-testing electrodiagnosis with chronaximetry Procedure site Skeletal muscle structure false Inferred relationship Existential restriction modifier 2
Muscle-testing electrodiagnosis with chronaximetry Is a Examination of muscle true Inferred relationship Existential restriction modifier
Muscle-testing electrodiagnosis with chronaximetry Is a Examination of body system true Inferred relationship Existential restriction modifier
Muscle-testing electrodiagnosis with chronaximetry Procedure site - Direct Skeletal muscle structure false Inferred relationship Existential restriction modifier 1
Muscle-testing electrodiagnosis with chronaximetry Method Functional assessment - action false Inferred relationship Existential restriction modifier 1
Muscle-testing electrodiagnosis with chronaximetry Using device Stimulator, device false Inferred relationship Existential restriction modifier 1
Muscle-testing electrodiagnosis with chronaximetry Procedure site - Direct Skeletal muscle structure true Inferred relationship Existential restriction modifier 1
Muscle-testing electrodiagnosis with chronaximetry Method Functional assessment - action true Inferred relationship Existential restriction modifier 1
Muscle-testing electrodiagnosis with chronaximetry Using device Stimulator, device true Inferred relationship Existential restriction modifier 1
Muscle-testing electrodiagnosis with chronaximetry Is a Evaluation of musculoskeletal system true Inferred relationship Existential restriction modifier

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start