FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

58632007: Repair of cardiac pulse generator (procedure)


Status: current, Sufficiently defined by necessary conditions definition status. Date: 31-Jan 2009. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
97431018 Repair of cardiac pulse generator en Synonym Active Entire term case insensitive SNOMED CT core module
797386011 Repair of cardiac pulse generator (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT core module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Repair of cardiac pulse generator Is a Repair of cardiac pacemaker true Inferred relationship Existential restriction modifier
Repair of cardiac pulse generator Method Maintenance - action false Inferred relationship Existential restriction modifier 1
Repair of cardiac pulse generator Procedure site Cardiac structure false Inferred relationship Existential restriction modifier
Repair of cardiac pulse generator Direct device Cardiac pacemaker, device false Inferred relationship Existential restriction modifier 2
Repair of cardiac pulse generator Method Management - action false Inferred relationship Existential restriction modifier
Repair of cardiac pulse generator Method Maintenance - action false Inferred relationship Existential restriction modifier 1
Repair of cardiac pulse generator Direct device Cardiac pacemaker, device false Inferred relationship Existential restriction modifier 1
Repair of cardiac pulse generator Direct device Pacemaker pulse generator, device false Inferred relationship Existential restriction modifier 1
Repair of cardiac pulse generator Method Repair - action false Inferred relationship Existential restriction modifier 1
Repair of cardiac pulse generator Procedure device Cardiac pacemaker, device false Inferred relationship Existential restriction modifier 2
Repair of cardiac pulse generator Procedure site - Indirect Heart structure false Inferred relationship Existential restriction modifier 1
Repair of cardiac pulse generator Is a Procedure by method false Inferred relationship Existential restriction modifier
Repair of cardiac pulse generator Is a Cardiac pacemaker procedure false Inferred relationship Existential restriction modifier
Repair of cardiac pulse generator Is a Procedure categorized by device involved false Inferred relationship Existential restriction modifier
Repair of cardiac pulse generator Is a Procedure on heart false Inferred relationship Existential restriction modifier
Repair of cardiac pulse generator Method Maintenance - action false Inferred relationship Existential restriction modifier 1
Repair of cardiac pulse generator Procedure site - Indirect Heart structure false Inferred relationship Existential restriction modifier 1
Repair of cardiac pulse generator Direct device Pacemaker pulse generator, device true Inferred relationship Existential restriction modifier 1
Repair of cardiac pulse generator Direct device Pacemaker pulse generator, device false Inferred relationship Existential restriction modifier 1
Repair of cardiac pulse generator Method Mechanical repair - action false Inferred relationship Existential restriction modifier 1
Repair of cardiac pulse generator Method Mechanical repair - action true Inferred relationship Existential restriction modifier 1

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start