FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

565161000000105: Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis (procedure)


    Status: retired, Not sufficiently defined by necessary conditions definition status. Date: 01-Apr 2011. Module: SNOMED CT United Kingdom clinical extension module

    Descriptions:

    Id Description Lang Type Status Case? Module
    1256881000000118 Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis (procedure) en Fully specified name Active Only initial character case insensitive SNOMED CT United Kingdom clinical extension module
    1256891000000116 Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis en Synonym Active Only initial character case insensitive SNOMED CT United Kingdom clinical extension module


    0 descendants.

    Expanded Value Set


    Outbound Relationships Type Target Active Characteristic Refinability Group Values
    Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Is a Creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis false Inferred relationship Existential restriction modifier
    Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Method Side-to-side anastomosis false Inferred relationship Existential restriction modifier 1
    Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Procedure site - Direct Structure of subclavian artery false Inferred relationship Existential restriction modifier 1
    Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Method Side-to-side anastomosis false Inferred relationship Existential restriction modifier 2
    Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Procedure site - Direct Pulmonary artery structure false Inferred relationship Existential restriction modifier 2
    Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Procedure site - Direct Pulmonary artery structure false Inferred relationship Existential restriction modifier 3
    Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Using device Interposition shunt false Inferred relationship Existential restriction modifier 3
    Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Method Shunt - action false Inferred relationship Existential restriction modifier 3
    Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Procedure site - Indirect Structure of pulmonary artery within lung false Inferred relationship Existential restriction modifier 3
    Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Method Shunt - action false Inferred relationship Existential restriction modifier 4
    Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Procedure site - Indirect Structure of pulmonary artery within lung false Inferred relationship Existential restriction modifier 4
    Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Using device Shunt false Inferred relationship Existential restriction modifier 4
    Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Procedure site - Direct Intrathoracic arterial structure false Inferred relationship Existential restriction modifier 4
    Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Procedure site - Direct Structure of subclavian artery false Inferred relationship Existential restriction modifier 5
    Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Using device Interposition shunt false Inferred relationship Existential restriction modifier 5
    Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Method Shunt - action false Inferred relationship Existential restriction modifier 5
    Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Procedure site - Indirect Structure of pulmonary artery within lung false Inferred relationship Existential restriction modifier 5
    Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Using device Interposition shunt false Inferred relationship Existential restriction modifier 6
    Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Procedure site - Direct Structure of subclavian artery false Inferred relationship Existential restriction modifier 6
    Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Method Shunt - action false Inferred relationship Existential restriction modifier 6
    Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Procedure site - Indirect Structure of pulmonary artery within lung false Inferred relationship Existential restriction modifier 6
    Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Using device Interposition shunt false Inferred relationship Existential restriction modifier 7
    Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Procedure site - Direct Structure of subclavian artery false Inferred relationship Existential restriction modifier 7
    Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Method Shunt - action false Inferred relationship Existential restriction modifier 7
    Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Procedure site - Indirect Structure of pulmonary artery within lung false Inferred relationship Existential restriction modifier 7

    Inbound Relationships Type Active Source Characteristic Refinability Group

    This concept is not in any reference sets