FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

431645008: Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast (procedure)


Status: current, Sufficiently defined by necessary conditions definition status. Date: 31-Jul 2008. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
4009128015 Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast en Synonym Active Entire term case insensitive SNOMED CT core module
4009129011 Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT core module
2845681000000118 Fluoroscopy guided percutaneous insertion of catheter into inferior vena cava with contrast en Synonym Active Entire term case insensitive SNOMED CT United Kingdom Edition module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast Is a Trunk implantation false Inferred relationship Existential restriction modifier
Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast Is a Fluoroscopic venography of inferior vena cava with contrast true Inferred relationship Existential restriction modifier
Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast Is a Insertion using fluoroscopic guidance true Inferred relationship Existential restriction modifier
Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast Is a Catheterization true Inferred relationship Existential restriction modifier
Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast Is a Vein implantation false Inferred relationship Existential restriction modifier
Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast Has intent Guidance intent false Inferred relationship Existential restriction modifier 1
Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast Method Fluoroscopic imaging - action false Inferred relationship Existential restriction modifier 1
Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast Access Percutaneous approach - access false Inferred relationship Existential restriction modifier 2
Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast Method Insertion - action false Inferred relationship Existential restriction modifier 2
Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast Direct device Catheter, device false Inferred relationship Existential restriction modifier 2
Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast Procedure site - Direct Inferior vena cava structure false Inferred relationship Existential restriction modifier 1
Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast Procedure site - Indirect Inferior vena cava structure false Inferred relationship Existential restriction modifier 2
Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast Procedure site - Direct Inferior vena cava structure true Inferred relationship Existential restriction modifier 1
Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast Has intent Guidance intent true Inferred relationship Existential restriction modifier 1
Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast Method Fluoroscopic imaging - action true Inferred relationship Existential restriction modifier 1
Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast Access Percutaneous approach - access true Inferred relationship Existential restriction modifier 2
Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast Direct device Catheter, device true Inferred relationship Existential restriction modifier 2
Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast Procedure site - Indirect Inferior vena cava structure true Inferred relationship Existential restriction modifier 2
Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast Method Insertion - action true Inferred relationship Existential restriction modifier 2
Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast Using substance Contrast media true Inferred relationship Existential restriction modifier 1

Inbound Relationships Type Active Source Characteristic Refinability Group
Percutaneous insertion of catheter into hepatic vein using fluoroscopic guidance with contrast Is a False Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast Inferred relationship Existential restriction modifier

This concept is not in any reference sets

Back to Start