FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

33284002: Check artificial pacemaker for amperage threshold (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status. Date: 31-Jan 2002. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
55544017 Check artificial pacemaker for amperage threshold en Synonym Active Entire term case insensitive SNOMED CT core module
764668017 Check artificial pacemaker for amperage threshold (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT core module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Check artificial pacemaker for amperage threshold Is a Check artificial pacemaker true Inferred relationship Existential restriction modifier
Check artificial pacemaker for amperage threshold Is a Maintenance procedure for cardiac pacemaker system true Inferred relationship Existential restriction modifier
Check artificial pacemaker for amperage threshold Method Maintenance - action false Inferred relationship Existential restriction modifier 1
Check artificial pacemaker for amperage threshold Procedure site Cardiac structure false Inferred relationship Existential restriction modifier
Check artificial pacemaker for amperage threshold Direct device Cardiac pacemaker, device false Inferred relationship Existential restriction modifier 1
Check artificial pacemaker for amperage threshold Method Management - action false Inferred relationship Existential restriction modifier
Check artificial pacemaker for amperage threshold Method Maintenance - action false Inferred relationship Existential restriction modifier 1
Check artificial pacemaker for amperage threshold Procedure device Device false Inferred relationship Existential restriction modifier 1
Check artificial pacemaker for amperage threshold Procedure device Cardiac pacemaker, device false Inferred relationship Existential restriction modifier 1
Check artificial pacemaker for amperage threshold Is a Maintenance of device false Inferred relationship Existential restriction modifier
Check artificial pacemaker for amperage threshold Procedure site - Indirect Heart structure false Inferred relationship Existential restriction modifier 1
Check artificial pacemaker for amperage threshold Direct device Cardiac pacemaker, device false Inferred relationship Existential restriction modifier 1
Check artificial pacemaker for amperage threshold Direct device Cardiac implant false Inferred relationship Existential restriction modifier 1
Check artificial pacemaker for amperage threshold Method Maintenance - action false Inferred relationship Existential restriction modifier 1
Check artificial pacemaker for amperage threshold Direct device Cardiac pacemaker, device false Inferred relationship Existential restriction modifier 1
Check artificial pacemaker for amperage threshold Procedure device Cardiac pacemaker, device true Inferred relationship Existential restriction modifier 1

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets