FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

313934006: 24 hour urine copper output measurement (procedure)


Status: current, Sufficiently defined by necessary conditions definition status. Date: 31-Jul 2004. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
458152014 24 hour urine copper output en Synonym Active Entire term case sensitive SNOMED CT core module
458153016 24 hour urine copper output measurement en Synonym Active Entire term case sensitive SNOMED CT core module
710698019 24 hour urine copper output measurement (procedure) en Fully specified name Active Entire term case sensitive SNOMED CT core module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
24 hour urine copper output measurement Is a Copper measurement false Inferred relationship Existential restriction modifier
24 hour urine copper output measurement Has measured component Copper false Inferred relationship Existential restriction modifier
24 hour urine copper output measurement Method Investigation - action false Inferred relationship Existential restriction modifier
24 hour urine copper output measurement Has intent Diagnostic intent false Inferred relationship Existential restriction modifier
24 hour urine copper output measurement Has specimen 24 hour urine specimen true Inferred relationship Existential restriction modifier 1
24 hour urine copper output measurement Component Copper true Inferred relationship Existential restriction modifier 2
24 hour urine copper output measurement Method Evaluation - action false Inferred relationship Existential restriction modifier
24 hour urine copper output measurement Is a 24 hour urine measurement true Inferred relationship Existential restriction modifier
24 hour urine copper output measurement Is a Measurement of substance in specimen false Inferred relationship Existential restriction modifier
24 hour urine copper output measurement Method Measurement - action true Inferred relationship Existential restriction modifier 3
24 hour urine copper output measurement Is a Copper measurement, urine true Inferred relationship Existential restriction modifier
24 hour urine copper output measurement PBCL flag true PBCL flag true: report, request, level, test false Additional relationship Existential restriction modifier
24 hour urine copper output measurement PBCL flag true PBCL flag true: report, request, level, test false Additional relationship Existential restriction modifier
24 hour urine copper output measurement PBCL flag true PBCL flag true: report, request, battery, level, test false Additional relationship Existential restriction modifier

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start