FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

303898003: Tc99m-labeled colloid spleen study - dynamic (procedure)


    Status: retired, Not sufficiently defined by necessary conditions definition status. Date: 31-Jul 2018. Module: SNOMED CT core module

    Descriptions:

    Id Description Lang Type Status Case? Module
    446127012 Tc99m-labelled colloid spleen study - dynamic en Synonym Active Entire term case sensitive SNOMED CT core module
    2869561011 Tc99m-labeled colloid spleen study - dynamic (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT core module
    2872418010 Tc99m-labeled colloid spleen study - dynamic en Synonym Active Entire term case insensitive SNOMED CT core module


    0 descendants.

    Expanded Value Set


    Outbound Relationships Type Target Active Characteristic Refinability Group Values
    Tc99m-labeled colloid spleen study - dynamic Is a Spleen imaging false Inferred relationship Existential restriction modifier
    Tc99m-labeled colloid spleen study - dynamic Procedure site Splenic structure false Inferred relationship Existential restriction modifier 1
    Tc99m-labeled colloid spleen study - dynamic Method Investigation - action false Inferred relationship Existential restriction modifier 2
    Tc99m-labeled colloid spleen study - dynamic Method Radionuclide imaging - action false Inferred relationship Existential restriction modifier 1
    Tc99m-labeled colloid spleen study - dynamic Method Radionuclide imaging - action false Inferred relationship Existential restriction modifier 3
    Tc99m-labeled colloid spleen study - dynamic Has intent Diagnostic intent false Inferred relationship Existential restriction modifier
    Tc99m-labeled colloid spleen study - dynamic Procedure site Abdominopelvic structure false Inferred relationship Existential restriction modifier 3
    Tc99m-labeled colloid spleen study - dynamic Is a Radioisotope study of hematopoietic system false Inferred relationship Existential restriction modifier
    Tc99m-labeled colloid spleen study - dynamic Is a Spleen imaging false Inferred relationship Existential restriction modifier
    Tc99m-labeled colloid spleen study - dynamic Direct substance Radioactive isotope false Inferred relationship Existential restriction modifier
    Tc99m-labeled colloid spleen study - dynamic Is a Radionuclide study of abdomen false Inferred relationship Existential restriction modifier
    Tc99m-labeled colloid spleen study - dynamic Method Introduction - action false Inferred relationship Existential restriction modifier
    Tc99m-labeled colloid spleen study - dynamic Direct substance Radioactive isotope false Inferred relationship Existential restriction modifier 1
    Tc99m-labeled colloid spleen study - dynamic Is a Radioisotope scan of spleen false Inferred relationship Existential restriction modifier
    Tc99m-labeled colloid spleen study - dynamic Using substance Radioactive isotope false Inferred relationship Existential restriction modifier 1
    Tc99m-labeled colloid spleen study - dynamic Procedure site - Direct Splenic structure false Inferred relationship Existential restriction modifier 1
    Tc99m-labeled colloid spleen study - dynamic Using substance Radioactive isotope false Inferred relationship Existential restriction modifier 1
    Tc99m-labeled colloid spleen study - dynamic Method Radionuclide imaging - action false Inferred relationship Existential restriction modifier 1
    Tc99m-labeled colloid spleen study - dynamic Procedure site - Direct Splenic structure false Inferred relationship Existential restriction modifier 1

    Inbound Relationships Type Active Source Characteristic Refinability Group
    Tc99m-labeled colloid liver and spleen study - dynamic Is a False Tc99m-labeled colloid spleen study - dynamic Inferred relationship Existential restriction modifier
    Radionuclide first pass spleen study Is a False Tc99m-labeled colloid spleen study - dynamic Inferred relationship Existential restriction modifier