FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

272235006: Interposition shunt (physical object)


Status: current, Not sufficiently defined by necessary conditions definition status. Date: 31-Jan 2002. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
407308017 Interposition shunt en Synonym Active Entire term case insensitive SNOMED CT core module
664735017 Interposition shunt (physical object) en Fully specified name Active Entire term case insensitive SNOMED CT core module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Interposition shunt Is a Shunt true Inferred relationship Existential restriction modifier

Inbound Relationships Type Active Source Characteristic Refinability Group
Construction of central aortopulmonary interposition shunt Using device True Interposition shunt Inferred relationship Existential restriction modifier 2
Construction of central aortopulmonary interposition shunt Using device True Interposition shunt Inferred relationship Existential restriction modifier 1
Creation of shunt from ascending aorta to right pulmonary artery using interposition tube prosthesis Using device True Interposition shunt Inferred relationship Existential restriction modifier 1
Creation of shunt from ascending aorta to right pulmonary artery using interposition tube prosthesis Using device True Interposition shunt Inferred relationship Existential restriction modifier 2
Creation of shunt from ascending aorta to left pulmonary artery using interposition tube prosthesis Using device True Interposition shunt Inferred relationship Existential restriction modifier 1
Creation of shunt from ascending aorta to left pulmonary artery using interposition tube prosthesis Using device True Interposition shunt Inferred relationship Existential restriction modifier 2
Creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Using device True Interposition shunt Inferred relationship Existential restriction modifier 1
Creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Using device True Interposition shunt Inferred relationship Existential restriction modifier 2
Creation of shunt from right subclavian artery to right pulmonary artery using interposition tube prosthesis Using device True Interposition shunt Inferred relationship Existential restriction modifier 2
Creation of shunt from right subclavian artery to right pulmonary artery using interposition tube prosthesis Using device True Interposition shunt Inferred relationship Existential restriction modifier 1
Creation of shunt from left subclavian artery to left pulmonary artery using interposition tube prosthesis Using device True Interposition shunt Inferred relationship Existential restriction modifier 1
Creation of shunt from left subclavian artery to left pulmonary artery using interposition tube prosthesis Using device True Interposition shunt Inferred relationship Existential restriction modifier 2
Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Using device False Interposition shunt Inferred relationship Existential restriction modifier 6
Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Using device False Interposition shunt Inferred relationship Existential restriction modifier 7
Creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis NOS Using device False Interposition shunt Inferred relationship Existential restriction modifier 6
Creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis NOS Using device False Interposition shunt Inferred relationship Existential restriction modifier 7
Creation of shunt from aorta to pulmonary artery using interposition tube prosthesis Using device True Interposition shunt Inferred relationship Existential restriction modifier 1
Creation of shunt from aorta to pulmonary artery using interposition tube prosthesis Using device True Interposition shunt Inferred relationship Existential restriction modifier 2
Percutaneous transluminal balloon dilatation of interposition tube prosthesis between pulmonary artery and subclavian artery Direct device True Interposition shunt Inferred relationship Existential restriction modifier 2
Percutaneous transluminal balloon dilatation of interposition tube prosthesis between pulmonary artery and aorta Direct device True Interposition shunt Inferred relationship Existential restriction modifier 1
Percutaneous transluminal occlusion of interposition tube prosthesis between pulmonary artery and subclavian artery Direct device True Interposition shunt Inferred relationship Existential restriction modifier 1
Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Using device False Interposition shunt Inferred relationship Existential restriction modifier 3
Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Using device False Interposition shunt Inferred relationship Existential restriction modifier 5
Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Using device False Interposition shunt Inferred relationship Existential restriction modifier 6
Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis Using device False Interposition shunt Inferred relationship Existential restriction modifier 7
Creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis NOS Using device False Interposition shunt Inferred relationship Existential restriction modifier 3
Creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis NOS Using device False Interposition shunt Inferred relationship Existential restriction modifier 5
Creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis NOS Using device False Interposition shunt Inferred relationship Existential restriction modifier 6
Creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis NOS Using device False Interposition shunt Inferred relationship Existential restriction modifier 7

This concept is not in any reference sets

Back to Start