252762003: Interference pattern electromyography analysis (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status. Date: 31-Jan 2002. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
376483012 Interference pattern EMG analysis en Synonym Active Only initial character case insensitive SNOMED CT core module
2972523012 Interference pattern electromyography analysis en Synonym Active Entire term case insensitive SNOMED CT core module
2972702016 Interference pattern electromyography analysis (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT core module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Interference pattern electromyography analysis Is a Quantitative electromyography analysis true Inferred relationship Existential restriction modifier
Interference pattern electromyography analysis Procedure site Neuromuscular junction false Inferred relationship Existential restriction modifier
Interference pattern electromyography analysis Method Investigation - action false Inferred relationship Existential restriction modifier
Interference pattern electromyography analysis Has intent Diagnostic intent true Inferred relationship Existential restriction modifier 1
Interference pattern electromyography analysis Has intent Therapeutic intent false Inferred relationship Existential restriction modifier
Interference pattern electromyography analysis Method Evaluation - action false Inferred relationship Existential restriction modifier 1
Interference pattern electromyography analysis Procedure site Skeletal muscle system structure false Inferred relationship Existential restriction modifier 3
Interference pattern electromyography analysis Procedure site Peripheral nervous system structure true Inferred relationship Existential restriction modifier 2
Interference pattern electromyography analysis Procedure site Skeletal and/or smooth muscle structure false Inferred relationship Existential restriction modifier 2
Interference pattern electromyography analysis Method Evaluation - action false Inferred relationship Existential restriction modifier 2
Interference pattern electromyography analysis Method Evaluation - action false Inferred relationship Existential restriction modifier 3
Interference pattern electromyography analysis Method Evaluation - action false Inferred relationship Existential restriction modifier 1
Interference pattern electromyography analysis Method Evaluation - action false Inferred relationship Existential restriction modifier 3
Interference pattern electromyography analysis Method Evaluation - action false Inferred relationship Existential restriction modifier 2
Interference pattern electromyography analysis Method Evaluation - action false Inferred relationship Existential restriction modifier 1
Interference pattern electromyography analysis Method Evaluation - action false Inferred relationship Existential restriction modifier 3
Interference pattern electromyography analysis Method Evaluation - action false Inferred relationship Existential restriction modifier 2
Interference pattern electromyography analysis Procedure site Skeletal muscle structure false Inferred relationship Existential restriction modifier 2
Interference pattern electromyography analysis Method Evaluation - action false Inferred relationship Existential restriction modifier 1
Interference pattern electromyography analysis Method Evaluation - action false Inferred relationship Existential restriction modifier 2
Interference pattern electromyography analysis Method Evaluation - action false Inferred relationship Existential restriction modifier 1
Interference pattern electromyography analysis Method Evaluation - action false Inferred relationship Existential restriction modifier 2
Interference pattern electromyography analysis Using device Electromyographic monitor and recorder, device false Inferred relationship Existential restriction modifier 1
Interference pattern electromyography analysis Procedure site - Direct Neuron-muscle motor unit false Inferred relationship Existential restriction modifier 1
Interference pattern electromyography analysis Procedure site - Direct Structure of nervous system false Inferred relationship Existential restriction modifier 3
Interference pattern electromyography analysis Method Evaluation - action true Inferred relationship Existential restriction modifier 2
Interference pattern electromyography analysis Method Evaluation - action false Inferred relationship Existential restriction modifier 1
Interference pattern electromyography analysis Method Evaluation - action false Inferred relationship Existential restriction modifier 3
Interference pattern electromyography analysis Method Evaluation - action false Inferred relationship Existential restriction modifier 2
Interference pattern electromyography analysis Procedure site - Direct Structure of nervous system true Inferred relationship Existential restriction modifier 3
Interference pattern electromyography analysis Method Evaluation - action true Inferred relationship Existential restriction modifier 3
Interference pattern electromyography analysis Using device Electromyographic monitor and recorder, device true Inferred relationship Existential restriction modifier 3
Interference pattern electromyography analysis Method Evaluation - action true Inferred relationship Existential restriction modifier 4
Interference pattern electromyography analysis Using device Electromyographic monitor and recorder, device true Inferred relationship Existential restriction modifier 4
Interference pattern electromyography analysis Procedure site - Direct Structure of neuron-muscle motor unit true Inferred relationship Existential restriction modifier 4

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start