FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

233070000: Open insertion of right ventricular catheter (procedure)


Status: current, Sufficiently defined by necessary conditions definition status. Date: 31-Jan 2002. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
349196011 Open insertion of right ventricular catheter en Synonym Active Entire term case insensitive SNOMED CT core module
621212016 Open insertion of right ventricular catheter (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT core module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Open insertion of right ventricular catheter Is a Operation on the right ventricular outflow tract false Inferred relationship Existential restriction modifier
Open insertion of right ventricular catheter Is a Catheterization of right heart true Inferred relationship Existential restriction modifier
Open insertion of right ventricular catheter Is a Mediastinum implantation false Inferred relationship Existential restriction modifier
Open insertion of right ventricular catheter Is a Open mediastinal procedure false Inferred relationship Existential restriction modifier
Open insertion of right ventricular catheter Procedure site Right cardiac ventricular structure false Inferred relationship Existential restriction modifier 1
Open insertion of right ventricular catheter Direct device Vascular catheter false Inferred relationship Existential restriction modifier 2
Open insertion of right ventricular catheter Method Surgical action false Inferred relationship Existential restriction modifier
Open insertion of right ventricular catheter Procedure site Structure of outflow tract of right ventricle false Inferred relationship Existential restriction modifier 1
Open insertion of right ventricular catheter Access Open approach - access true Inferred relationship Existential restriction modifier 1
Open insertion of right ventricular catheter Method Implantation - action false Inferred relationship Existential restriction modifier 1
Open insertion of right ventricular catheter Direct device Appliance false Inferred relationship Existential restriction modifier
Open insertion of right ventricular catheter Direct device Catheter, device false Inferred relationship Existential restriction modifier
Open insertion of right ventricular catheter Procedure site Structure of right side of heart false Inferred relationship Existential restriction modifier 3
Open insertion of right ventricular catheter Using Catheter, device false Inferred relationship Existential restriction modifier
Open insertion of right ventricular catheter Method Insertion - action false Inferred relationship Existential restriction modifier 1
Open insertion of right ventricular catheter Method Insertion - action false Inferred relationship Existential restriction modifier 1
Open insertion of right ventricular catheter Direct device Catheter, device false Inferred relationship Existential restriction modifier
Open insertion of right ventricular catheter Method Insertion - action false Inferred relationship Existential restriction modifier 2
Open insertion of right ventricular catheter Method Insertion - action false Inferred relationship Existential restriction modifier 2
Open insertion of right ventricular catheter Direct device Implant, device false Inferred relationship Existential restriction modifier
Open insertion of right ventricular catheter Method Insertion - action false Inferred relationship Existential restriction modifier 2
Open insertion of right ventricular catheter Method Insertion - action false Inferred relationship Existential restriction modifier 3
Open insertion of right ventricular catheter Procedure site Heart structure false Inferred relationship Existential restriction modifier 2
Open insertion of right ventricular catheter Method Insertion - action false Inferred relationship Existential restriction modifier 1
Open insertion of right ventricular catheter Method Insertion - action false Inferred relationship Existential restriction modifier 3
Open insertion of right ventricular catheter Method Insertion - action false Inferred relationship Existential restriction modifier 2
Open insertion of right ventricular catheter Method Insertion - action false Inferred relationship Existential restriction modifier 3
Open insertion of right ventricular catheter Method Insertion - action false Inferred relationship Existential restriction modifier 1
Open insertion of right ventricular catheter Method Insertion - action false Inferred relationship Existential restriction modifier 2
Open insertion of right ventricular catheter Method Insertion - action false Inferred relationship Existential restriction modifier 1
Open insertion of right ventricular catheter Method Insertion - action false Inferred relationship Existential restriction modifier 2
Open insertion of right ventricular catheter Method Insertion - action false Inferred relationship Existential restriction modifier 3
Open insertion of right ventricular catheter Method Insertion - action false Inferred relationship Existential restriction modifier 1
Open insertion of right ventricular catheter Method Insertion - action false Inferred relationship Existential restriction modifier 2
Open insertion of right ventricular catheter Method Insertion - action false Inferred relationship Existential restriction modifier 3
Open insertion of right ventricular catheter Procedure site - Indirect Right cardiac ventricular structure true Inferred relationship Existential restriction modifier 1
Open insertion of right ventricular catheter Procedure site - Indirect Structure of right side of heart false Inferred relationship Existential restriction modifier 2
Open insertion of right ventricular catheter Method Insertion - action true Inferred relationship Existential restriction modifier 1
Open insertion of right ventricular catheter Method Insertion - action false Inferred relationship Existential restriction modifier 2
Open insertion of right ventricular catheter Direct device Vascular catheter true Inferred relationship Existential restriction modifier 1
Open insertion of right ventricular catheter Direct device Vascular catheter false Inferred relationship Existential restriction modifier 2

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start