FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.8.2  |  FHIR Version n/a  User: [n/a]

231039001: Implantation of neurostimulator electrode onto spinal nerve root (procedure)


Status: current, Sufficiently defined by necessary conditions definition status. Date: 31-Jan 2002. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
346127013 Implantation of neurostimulator electrode onto spinal nerve root en Synonym Active Entire term case insensitive SNOMED CT core module
618924013 Implantation of neurostimulator electrode onto spinal nerve root (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT core module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Implantation of neurostimulator electrode onto spinal nerve root Is a Neurostimulation procedures of spinal nerve root false Inferred relationship Existential restriction modifier
Implantation of neurostimulator electrode onto spinal nerve root Is a Insertion of pacemaker into peripheral nerve false Inferred relationship Existential restriction modifier
Implantation of neurostimulator electrode onto spinal nerve root Method Implantation - action true Inferred relationship Existential restriction modifier 1
Implantation of neurostimulator electrode onto spinal nerve root Procedure site Spinal nerve root structure false Inferred relationship Existential restriction modifier 2
Implantation of neurostimulator electrode onto spinal nerve root Procedure site Structure of spinal cord root and/or ganglion false Inferred relationship Existential restriction modifier
Implantation of neurostimulator electrode onto spinal nerve root Direct device Neurostimulator, device false Inferred relationship Existential restriction modifier
Implantation of neurostimulator electrode onto spinal nerve root Direct device Neurostimulator electrode false Inferred relationship Existential restriction modifier 1
Implantation of neurostimulator electrode onto spinal nerve root Method Insertion - action false Inferred relationship Existential restriction modifier 1
Implantation of neurostimulator electrode onto spinal nerve root Method Stimulation - action false Inferred relationship Existential restriction modifier 2
Implantation of neurostimulator electrode onto spinal nerve root Procedure site Peripheral nerve structure false Inferred relationship Existential restriction modifier 2
Implantation of neurostimulator electrode onto spinal nerve root Is a Implantation of electrode into peripheral nerve true Inferred relationship Existential restriction modifier
Implantation of neurostimulator electrode onto spinal nerve root Procedure site Structure of nervous system false Inferred relationship Existential restriction modifier 1
Implantation of neurostimulator electrode onto spinal nerve root Procedure device Neurostimulator, device false Inferred relationship Existential restriction modifier 1
Implantation of neurostimulator electrode onto spinal nerve root Is a Procedure on organ true Inferred relationship Existential restriction modifier
Implantation of neurostimulator electrode onto spinal nerve root Procedure site - Indirect Spinal nerve root structure false Inferred relationship Existential restriction modifier 1
Implantation of neurostimulator electrode onto spinal nerve root Is a Peripheral nerve neurostimulator electrode procedures true Inferred relationship Existential restriction modifier
Implantation of neurostimulator electrode onto spinal nerve root Procedure site - Indirect Spinal nerve root structure true Inferred relationship Existential restriction modifier 1
Implantation of neurostimulator electrode onto spinal nerve root Method Insertion - action false Inferred relationship Existential restriction modifier 1
Implantation of neurostimulator electrode onto spinal nerve root Direct device Neurostimulator electrode true Inferred relationship Existential restriction modifier 1
Implantation of neurostimulator electrode onto spinal nerve root Is a Biomedical equipment procedure false Inferred relationship Existential restriction modifier
Implantation of neurostimulator electrode onto spinal nerve root Is a Insertion procedure false Inferred relationship Existential restriction modifier
Implantation of neurostimulator electrode onto spinal nerve root Is a Procedure on spine true Inferred relationship Existential restriction modifier

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start