Inbound Relationships |
Type |
Active |
Source |
Characteristic |
Refinability |
Group |
Catheter ablation of lesion of heart |
Using device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
2 |
Replacement of urinary catheter |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Injection of contrast media for radiography by catheter, selective |
Using access device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Intrauterine catheterization |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Injection of contrast media for radiography by catheter, non-selective |
Using access device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Injection of contrast media for radiography by catheter |
Using access device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Catheterization of bronchus |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Replacement of distal catheter in shunt system |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Removal of catheter |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Transcatheter therapy |
Using device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Checking position of urinary catheter |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Replacement of wound catheter of integument |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Attention to catheter |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Removal of catheter from subclavian vein |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Nasotracheobronchial catheter aspiration |
Indirect device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Endoscopy and catheterization |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Removal of catheter from internal jugular vein |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Replacement of catheter |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Insertion of catheter into cardiac ventricle for stimulation using fluoroscopy guidance |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
2 |
Removal of catheter from external jugular vein |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Replacement of percutaneous drainage catheter with contrast monitoring |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
2 |
Catheterization with bronchial brush biopsy |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
2 |
Insertion of catheter into spinal canal for infusion of therapeutic substance |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Conductance catheter method |
Using device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Irrigation of wound catheter of integument |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Change of percutaneous biliary drainage catheter |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Removal of urinary system catheter |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Catheterization of ureter |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Catheterization of bronchus with lavage |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Insertion of catheter in spinal canal space, epidural, subarachnoid or subdural, for infusion of therapeutic or palliative substances |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Percutaneous insertion of catheter into hepatic vein using fluoroscopic guidance with contrast |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
2 |
Thrombolysis of access catheter |
Indirect device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Removal of pulmonary artery catheter using fluoroscopic guidance with contrast |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
2 |
Insertion of catheter into pulmonary artery using fluoroscopic guidance with contrast |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
2 |
Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
2 |
Percutaneous insertion of catheter into renal vein using fluoroscopic guidance with contrast |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
2 |
Insertion of apheresis catheter using fluoroscopic guidance with contrast |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Insertion of radioactive implant into interstitial tissue of prostate with transperineal insertion of catheter |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
2 |
Stereotactic insertion of intracerebral infusion catheter |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Percutaneous insertion of catheter into hepatic vein using fluoroscopic guidance with contrast |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
2 |
Percutaneous insertion of catheter into inferior vena cava using fluoroscopic guidance with contrast |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
2 |
Percutaneous insertion of catheter into renal vein using fluoroscopic guidance with contrast |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
2 |
Transcatheter instillation of substance into pleural cavity |
Using device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Insertion of tunneled indwelling catheter with cuff into pleura |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Insertion of apheresis catheter using fluoroscopic guidance with contrast |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Umbilical vessel catheterization |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Thrombolysis of access catheter |
Indirect device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Transcatheter therapy by infusion with angiography |
Using device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
3 |
Insertion of catheter into cardiac ventricle for stimulation using fluoroscopy guidance |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
2 |
Retrograde catheter ureteropyelography |
Using access device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Bronchoscopy and insertion of intracavitary radioactive isotope using catheter |
Using device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
2 |
Insertion of afterloading balloon catheter for radiotherapy into breast using imaging guidance |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Transcatheter insertion of radiation delivery device for intravascular coronary brachytherapy |
Using access device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Insertion of afterloading brachytherapy catheter for radiotherapy into breast using imaging guidance |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Insertion of afterloading balloon catheter for radiotherapy into breast using imaging guidance |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Bronchoscopy and insertion of intracavitary radioactive isotope using catheter |
Using device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
2 |
Insertion of catheter into pulmonary artery using fluoroscopic guidance with contrast |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
2 |
Transcatheter insertion of radiation delivery device for intravascular coronary brachytherapy |
Using access device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Insertion of tunneled indwelling catheter with cuff into pleura |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Insertion of afterloading brachytherapy catheter for radiotherapy into breast using imaging guidance |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Removal of pulmonary artery catheter using fluoroscopic guidance with contrast |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
2 |
Stereotactic insertion of intracerebral infusion catheter |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Bronchus catheterized |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Percutaneous transhepatic insertion of catheter into biliary tract using radiologic guidance with contrast |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Insertion of balloon catheter into breast for radiotherapy |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Bronchus catheterized |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Therapeutic drainage of amniotic fluid by indwelling catheter |
Using device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Replacement of biliary catheter using fluoroscopic guidance with contrast |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Percutaneous transhepatic insertion of catheter into biliary tract using radiologic guidance with contrast |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Insertion of balloon catheter into breast for radiotherapy |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Replacement of biliary catheter using fluoroscopic guidance with contrast |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Fluoroscopy of catheter in situ |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Tenckhoff catheter |
Is a |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
|
Umbilical catheter |
Is a |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
|
Insertion of catheter into spinal canal for infusion of palliative substances |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Fluoroscopy of catheter in situ |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Insertion of catheter into spinal canal for infusion of therapeutic substance |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Insertion of catheter in spinal canal space, epidural, subarachnoid or subdural, for infusion of therapeutic or palliative substances |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Insertion of catheter into brachial plexus |
Direct device |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Insertion of catheter into brachial plexus |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Catheterization of umbilical vein |
Direct device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Drainage of cyst of pancreas using catheter |
Using access device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Blocked catheter |
Associated with |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Infection associated with catheter |
Associated with |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
2 |
Infection of catheter exit site |
Associated with |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
3 |
Complication of catheter |
Associated with |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Swab from catheter |
Specimen source identity |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Migration of percutaneous transhepatic biliary drain catheter |
Associated with |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
1 |
Catheter ablation of arrhythmogenic focus |
Using device |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
2 |
Infusion/injection port, implantable |
Is a |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
|
Hemostasis valve |
Is a |
True |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
|
Hemostasis valve obturator |
Is a |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
|
Arterial pressure cardiac output/oximetry monitor |
Is a |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
|
Patient monitoring system module, blood pressure, invasive |
Is a |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
|
Patient monitoring system module, cardiac output |
Is a |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
|
Patient monitoring system module, intracardiac oximetry |
Is a |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
|
Anorectal brachytherapy system applicator, manual |
Is a |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
|
Anorectal brachytherapy system applicator, remote-afterloading |
Is a |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
|
Radio-frequency coronary angioplasty system |
Is a |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
|
Radio-frequency hyperthermia system applicator, intracorporeal |
Is a |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
|
Esophagus brachytherapy system applicator, manual |
Is a |
False |
Catheter, device |
Inferred relationship |
Existential restriction modifier |
|