FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.24  |  FHIR Version n/a  User: [n/a]

1255970003: Replacement of spinal segment of intrathecal catheter using fluoroscopic guidance (procedure)


Status: current, Sufficiently defined by necessary conditions definition status. Date: 30-Nov 2022. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
5150452014 Replacement of spinal segment of intrathecal catheter using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT core module
5150453016 Replacement of spinal segment of intrathecal catheter using fluoroscopic guidance en Synonym Active Entire term case insensitive SNOMED CT core module
5150454010 Replacement of spinal segment of microspinal catheter using fluoroscopic guidance en Synonym Active Entire term case insensitive SNOMED CT core module
5154990019 Fluoroscopy guided replacement of spinal segment of microspinal catheter en Synonym Active Entire term case insensitive SNOMED CT core module


1 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Replacement of spinal segment of intrathecal catheter using fluoroscopic guidance Is a Replacement of intrathecal catheter true Inferred relationship Existential restriction modifier
Replacement of spinal segment of intrathecal catheter using fluoroscopic guidance Is a Removal of intrathecal catheter using fluoroscopic guidance true Inferred relationship Existential restriction modifier
Replacement of spinal segment of intrathecal catheter using fluoroscopic guidance Method Replacement - action true Inferred relationship Existential restriction modifier 1
Replacement of spinal segment of intrathecal catheter using fluoroscopic guidance Procedure site - Indirect Subarachnoid space structure true Inferred relationship Existential restriction modifier 1
Replacement of spinal segment of intrathecal catheter using fluoroscopic guidance Direct device Spinal segment of microspinal catheter true Inferred relationship Existential restriction modifier 1
Replacement of spinal segment of intrathecal catheter using fluoroscopic guidance Method Fluoroscopic imaging - action true Inferred relationship Existential restriction modifier 2
Replacement of spinal segment of intrathecal catheter using fluoroscopic guidance Procedure site - Direct Subarachnoid space structure true Inferred relationship Existential restriction modifier 2
Replacement of spinal segment of intrathecal catheter using fluoroscopic guidance Has intent Guidance intent true Inferred relationship Existential restriction modifier 2

Inbound Relationships Type Active Source Characteristic Refinability Group
Replacement of intrathecal implantable infusion pump and spinal segment of intrathecal catheter using fluoroscopic guidance Is a True Replacement of spinal segment of intrathecal catheter using fluoroscopic guidance Inferred relationship Existential restriction modifier

This concept is not in any reference sets

Back to Start