FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

1153380009: Mechanical hemolysis following insertion of prosthetic heart valve (disorder)


Status: current, Sufficiently defined by necessary conditions definition status. Date: 31-Jul 2021. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
4564168019 Mechanical haemolysis due to prosthetic valve en Synonym Active Entire term case insensitive SNOMED CT core module
4564169010 Mechanical hemolysis following insertion of prosthetic heart valve (disorder) en Fully specified name Active Entire term case insensitive SNOMED CT core module
4564170011 Mechanical hemolysis following insertion of prosthetic heart valve en Synonym Active Entire term case insensitive SNOMED CT core module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Mechanical hemolysis following insertion of prosthetic heart valve Interprets Red blood cell count true Inferred relationship Existential restriction modifier 2
Mechanical hemolysis following insertion of prosthetic heart valve Has interpretation Below reference range true Inferred relationship Existential restriction modifier 4
Mechanical hemolysis following insertion of prosthetic heart valve Has interpretation Present true Inferred relationship Existential restriction modifier 3
Mechanical hemolysis following insertion of prosthetic heart valve Interprets Hemolysis true Inferred relationship Existential restriction modifier 3
Mechanical hemolysis following insertion of prosthetic heart valve Is a Traumatic cardiac hemolytic anemia true Inferred relationship Existential restriction modifier
Mechanical hemolysis following insertion of prosthetic heart valve Has interpretation Below reference range true Inferred relationship Existential restriction modifier 2
Mechanical hemolysis following insertion of prosthetic heart valve Finding site Erythrocyte true Inferred relationship Existential restriction modifier 5
Mechanical hemolysis following insertion of prosthetic heart valve Is a Postoperative complication true Inferred relationship Existential restriction modifier
Mechanical hemolysis following insertion of prosthetic heart valve Interprets Measurement of total hemoglobin concentration true Inferred relationship Existential restriction modifier 4
Mechanical hemolysis following insertion of prosthetic heart valve After Prosthetic replacement of heart valve true Inferred relationship Existential restriction modifier 1
Mechanical hemolysis following insertion of prosthetic heart valve Is a Hemoglobin below reference range true Inferred relationship Existential restriction modifier
Mechanical hemolysis following insertion of prosthetic heart valve Is a Red blood cell disorder true Inferred relationship Existential restriction modifier

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start