FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

105371005: Single photon emission computed tomography (procedure)


Status: current, Sufficiently defined by necessary conditions definition status. Date: 31-Jul 2008. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
169403014 Single photon emission computerized tomography en Synonym Active Entire term case insensitive SNOMED CT core module
289078019 Single photon emission computerised tomography en Synonym Active Entire term case insensitive SNOMED CT core module
4574869011 Single photon emission computed tomography en Synonym Active Entire term case insensitive SNOMED CT core module
4574870012 Single photon emission computed tomography (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT core module


127 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Single photon emission computed tomography Is a Positron emission tomography false Inferred relationship Existential restriction modifier
Single photon emission computed tomography Method Single photon emission computed tomography - action true Inferred relationship Existential restriction modifier 1
Single photon emission computed tomography Method Radionuclide imaging - action false Inferred relationship Existential restriction modifier
Single photon emission computed tomography Method Radiographic imaging - action false Inferred relationship Existential restriction modifier
Single photon emission computed tomography Has intent Diagnostic intent false Inferred relationship Existential restriction modifier
Single photon emission computed tomography Method Investigation - action false Inferred relationship Existential restriction modifier
Single photon emission computed tomography Using Positron emission tomography unit, device false Inferred relationship Existential restriction modifier
Single photon emission computed tomography Method Positron emission tomographic imaging - action false Inferred relationship Existential restriction modifier
Single photon emission computed tomography Has intent Diagnostic intent false Inferred relationship Existential restriction modifier
Single photon emission computed tomography Is a Imaging false Inferred relationship Existential restriction modifier
Single photon emission computed tomography Using substance Radioactive isotope false Inferred relationship Existential restriction modifier 1
Single photon emission computed tomography Method Single photon emission computed tomography - action false Inferred relationship Existential restriction modifier 1
Single photon emission computed tomography Using substance Radioactive isotope true Inferred relationship Existential restriction modifier 1
Single photon emission computed tomography Is a Nuclear medicine imaging procedure true Inferred relationship Existential restriction modifier

Inbound Relationships Type Active Source Characteristic Refinability Group
Single photon emission computed tomography for dopamine transport Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography technetium 99m sulesomab study Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography using technetium (99m-Tc) exametazine labeled leucocytes Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of kidney using dimercaptosuccinic acid Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of entire skeleton Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of brain using thallium Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of brain perfusion Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography ventriculography at cardiac rest Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography cardiac stress ventriculography Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of bone Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography indium 111 leukocyte study Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of whole body using iodine 131 Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography scintimammography Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography using iodine 131 meta-iodobenzylguanidine Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of parathyroid Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of tumor Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography using radiolabeled octreotide Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Kidney imaging, single photon emission computed tomography technique Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography using gallium Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of whole body using iodine 123 Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography using iodine 123 meta-iodobenzylguanidine Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of liver and spleen Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of lung Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of myocardial perfusion using technetium 99m meta-iodobenzylguanidine tetrofosmin Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of sentinel lymph node Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography with computed tomography Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of hemangioma of liver Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of neck Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of heart Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of liver Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of kidney Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of brain Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography for localization of inflammation Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of whole body for localization of abscess Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography using gallium radiolabeled white blood cells for localization of inflammation Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography using technetium (99m-Tc) sulesomab Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of perfusion of lung Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of bones of whole body Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography NEC Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computerised tomography bone study (procedure) Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computerised tomography whole body bone scan (procedure) Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computerised tomography brain perfusion study Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computerised tomography thallium brain study Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computerised tomography cardiac ventriculography stress study Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computerised tomography cardiac ventriculography rest study Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computerised tomography gallium study Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computerised tomography iodine 123 whole body study Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computerised tomography of liver and spleen Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computerised tomography iodine 123 meta-iodobenzylguanidine study Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computerised tomography iodine 131 meta-iodobenzylguanidine study Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computerised tomography octreotide study Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computerised tomography parathyroid study Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computerised tomography tumour imaging study Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computerised tomography scintimammography (procedure) Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computerised tomography of haemangioma of liver (procedure) Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computerised tomography dimercaptosuccinic acid renal study (procedure) Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computerised tomography indium 111 leucocyte study (procedure) Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computerised tomography iodine 131 whole body study Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computerised tomography technetium-99m hexamethylpropyleneamine oxime leucocyte scan Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computerised tomography technetium 99m sulesomab scan (procedure) Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of lung (procedure) Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of sentinel lymph node (procedure) Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography with computed tomography (procedure) Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of liver using technetium 99m macroaggregated albumin (procedure) Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of whole body (procedure) Is a True Single photon emission computed tomography Inferred relationship Existential restriction modifier
Single photon emission computed tomography of dopamine receptor sites of brain using 123I-ioflupane (procedure) Is a False Single photon emission computed tomography Inferred relationship Existential restriction modifier

This concept is not in any reference sets

Back to Start