FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.24  |  FHIR Version n/a  User: [n/a]

104720004: Hemoglobin, unstable measurement (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status. Date: 31-Jan 2002. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
168701019 Hemoglobin, unstable measurement en Synonym Active Entire term case insensitive SNOMED CT core module
281516015 Haemoglobin, unstable measurement en Synonym Active Entire term case insensitive SNOMED CT core module
281517012 Unstable hemoglobin detection en Synonym Active Entire term case insensitive SNOMED CT core module
281518019 Unstable haemoglobin detection en Synonym Active Entire term case insensitive SNOMED CT core module
565420010 Hemoglobin, unstable measurement (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT core module
1783477014 Unstable haemoglobin level en Synonym Active Entire term case insensitive SNOMED CT core module
1783846015 Unstable hemoglobin level en Synonym Active Entire term case insensitive SNOMED CT core module


1 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Hemoglobin, unstable measurement Is a Chemical procedure false Inferred relationship Existential restriction modifier
Hemoglobin, unstable measurement Is a Examination of specimen for hemolysis true Inferred relationship Existential restriction modifier
Hemoglobin, unstable measurement Has intent Diagnostic intent false Inferred relationship Existential restriction modifier
Hemoglobin, unstable measurement Method Investigation - action false Inferred relationship Existential restriction modifier
Hemoglobin, unstable measurement Has measured component Unstable hemoglobin false Inferred relationship Existential restriction modifier
Hemoglobin, unstable measurement Component Unstable hemoglobin true Inferred relationship Existential restriction modifier 1
Hemoglobin, unstable measurement Has specimen Red blood cell fluid specimen false Inferred relationship Existential restriction modifier
Hemoglobin, unstable measurement Component Hematology observable false Inferred relationship Existential restriction modifier
Hemoglobin, unstable measurement Method Evaluation - action false Inferred relationship Existential restriction modifier
Hemoglobin, unstable measurement Component Specimen observable false Inferred relationship Existential restriction modifier
Hemoglobin, unstable measurement Is a Protein measurement true Inferred relationship Existential restriction modifier
Hemoglobin, unstable measurement Is a Measurement of substance in specimen false Inferred relationship Existential restriction modifier
Hemoglobin, unstable measurement Method Measurement - action true Inferred relationship Existential restriction modifier 2
Hemoglobin, unstable measurement Component Erythrocyte true Inferred relationship Existential restriction modifier 3
Hemoglobin, unstable measurement PBCL flag true PBCL flag true: report, request, level, test, boolean false Additional relationship Existential restriction modifier
Hemoglobin, unstable measurement PBCL flag true PBCL flag true: report, request, level, test, boolean false Additional relationship Existential restriction modifier

Inbound Relationships Type Active Source Characteristic Refinability Group
Isopropanol precipitation test Is a True Hemoglobin, unstable measurement Inferred relationship Existential restriction modifier

This concept is not in any reference sets

Back to Start