Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2008. Module: SNOMED CT core
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
2769332012 | Dilatation of transjugular intrahepatic portosystemic shunt stent using fluoroscopic guidance | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
5275565015 | Dilation of transjugular intrahepatic portosystemic shunt stent using fluoroscopic guidance (procedure) | en | Fully specified name | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
5275566019 | Dilation of transjugular intrahepatic portosystemic shunt stent using fluoroscopic guidance | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Dilation of transjugular intrahepatic portosystemic shunt stent using fluoroscopic guidance (procedure) | Is a | Dilation using fluoroscopic guidance (procedure) | true | Inferred relationship | Some | ||
Dilation of transjugular intrahepatic portosystemic shunt stent using fluoroscopic guidance (procedure) | Is a | Procedure categorized by device involved | false | Inferred relationship | Some | ||
Dilation of transjugular intrahepatic portosystemic shunt stent using fluoroscopic guidance (procedure) | Indirect morphology | Transjugular intrahepatic portosystemic shunt (morphologic abnormality) | true | Inferred relationship | Some | 1 | |
Dilation of transjugular intrahepatic portosystemic shunt stent using fluoroscopic guidance (procedure) | Method | Dilation - action | false | Inferred relationship | Some | 2 | |
Dilation of transjugular intrahepatic portosystemic shunt stent using fluoroscopic guidance (procedure) | Direct device | Stent | true | Inferred relationship | Some | 2 | |
Dilation of transjugular intrahepatic portosystemic shunt stent using fluoroscopic guidance (procedure) | Method | Fluoroscopic imaging - action (qualifier value) | false | Inferred relationship | Some | 1 | |
Dilation of transjugular intrahepatic portosystemic shunt stent using fluoroscopic guidance (procedure) | Direct device | Stent | true | Inferred relationship | Some | 1 | |
Dilation of transjugular intrahepatic portosystemic shunt stent using fluoroscopic guidance (procedure) | Has intent | Guidance intent (qualifier value) | false | Inferred relationship | Some | 1 | |
Dilation of transjugular intrahepatic portosystemic shunt stent using fluoroscopic guidance (procedure) | Indirect morphology | Transjugular intrahepatic portosystemic shunt (morphologic abnormality) | false | Inferred relationship | Some | 2 | |
Dilation of transjugular intrahepatic portosystemic shunt stent using fluoroscopic guidance (procedure) | Is a | Venogram - portal vein | true | Inferred relationship | Some | ||
Dilation of transjugular intrahepatic portosystemic shunt stent using fluoroscopic guidance (procedure) | Is a | Operation on abdominal region | true | Inferred relationship | Some | ||
Dilation of transjugular intrahepatic portosystemic shunt stent using fluoroscopic guidance (procedure) | Is a | Soft tissue X-ray of abdomen | false | Inferred relationship | Some | ||
Dilation of transjugular intrahepatic portosystemic shunt stent using fluoroscopic guidance (procedure) | Is a | Fluoroscopy of abdomen | true | Inferred relationship | Some | ||
Dilation of transjugular intrahepatic portosystemic shunt stent using fluoroscopic guidance (procedure) | Is a | Operative procedure on vein (procedure) | true | Inferred relationship | Some | ||
Dilation of transjugular intrahepatic portosystemic shunt stent using fluoroscopic guidance (procedure) | Is a | Fluoroscopic venography (procedure) | true | Inferred relationship | Some | ||
Dilation of transjugular intrahepatic portosystemic shunt stent using fluoroscopic guidance (procedure) | Is a | Procedure on portal venous system using imaging guidance (procedure) | true | Inferred relationship | Some | ||
Dilation of transjugular intrahepatic portosystemic shunt stent using fluoroscopic guidance (procedure) | Method | Dilation - action | true | Inferred relationship | Some | 1 | |
Dilation of transjugular intrahepatic portosystemic shunt stent using fluoroscopic guidance (procedure) | Procedure site - Indirect (attribute) | Portal vein structure | true | Inferred relationship | Some | 1 | |
Dilation of transjugular intrahepatic portosystemic shunt stent using fluoroscopic guidance (procedure) | Method | Fluoroscopic imaging - action (qualifier value) | true | Inferred relationship | Some | 2 | |
Dilation of transjugular intrahepatic portosystemic shunt stent using fluoroscopic guidance (procedure) | Procedure site - Direct (attribute) | Portal vein structure | true | Inferred relationship | Some | 2 | |
Dilation of transjugular intrahepatic portosystemic shunt stent using fluoroscopic guidance (procedure) | Direct morphology | Transjugular intrahepatic portosystemic shunt (morphologic abnormality) | true | Inferred relationship | Some | 2 | |
Dilation of transjugular intrahepatic portosystemic shunt stent using fluoroscopic guidance (procedure) | Has intent | Guidance intent (qualifier value) | true | Inferred relationship | Some | 2 |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
This concept is not in any reference sets