FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.12  |  FHIR Version n/a  User: [n/a]

1259015007: Implantation of spinal cord stimulator generator and electrode (procedure)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 30-Nov 2022. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
5155420012 Implantation of spinal cord stimulator generator and electrode en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
5155421011 Implantation of spinal cord stimulator generator and electrode (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
5155422016 Implantation of permanent spinal cord stimulator en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
5155423014 Implantation of permanent spinal cord stimulator generator and electrode en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Implantation of spinal cord stimulator generator and electrode (procedure) Is a Procedure on trunk true Inferred relationship Some
Implantation of spinal cord stimulator generator and electrode (procedure) Is a Procedure on subcutaneous tissue false Inferred relationship Some
Implantation of spinal cord stimulator generator and electrode (procedure) Is a Implantation of electronic stimulator of spine true Inferred relationship Some
Implantation of spinal cord stimulator generator and electrode (procedure) Is a Implantation of neurostimulator device (procedure) false Inferred relationship Some
Implantation of spinal cord stimulator generator and electrode (procedure) Method Implantation - action true Inferred relationship Some 1
Implantation of spinal cord stimulator generator and electrode (procedure) Procedure site - Indirect (attribute) Spinal cord structure true Inferred relationship Some 1
Implantation of spinal cord stimulator generator and electrode (procedure) Direct device Neurostimulator electrode true Inferred relationship Some 1
Implantation of spinal cord stimulator generator and electrode (procedure) Method Implantation - action true Inferred relationship Some 2
Implantation of spinal cord stimulator generator and electrode (procedure) Procedure site - Indirect (attribute) Subcutaneous tissue structure of trunk (body structure) true Inferred relationship Some 2
Implantation of spinal cord stimulator generator and electrode (procedure) Direct device Implantable analgesic spinal cord electrical stimulation system pulse generator true Inferred relationship Some 2
Implantation of spinal cord stimulator generator and electrode (procedure) Is a Introduction of substance into subcutaneous tissue false Inferred relationship Some
Implantation of spinal cord stimulator generator and electrode (procedure) Is a Introduction into subcutaneous tissue true Inferred relationship Some
Implantation of spinal cord stimulator generator and electrode (procedure) Is a Implantation of neurostimulator device of spinal cord true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start