FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

1208762007: Persistent flow of blood into aneurysm sac following endovascular insertion of stent graft (disorder)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Mar 2022. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
4970869017 Endoleak en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
4970870016 Persistent flow of blood into aneurysm sac following endovascular insertion of stent graft (disorder) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
4970871017 Persistent flow of blood into aneurysm sac following endovascular insertion of stent graft en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Persistent flow of blood into aneurysm sac following endovascular insertion of stent graft (disorder) Is a Vascular disorder true Inferred relationship Some
Persistent flow of blood into aneurysm sac following endovascular insertion of stent graft (disorder) Is a Disorder following clinical procedure false Inferred relationship Some
Persistent flow of blood into aneurysm sac following endovascular insertion of stent graft (disorder) After Endovascular insertion of stent graft true Inferred relationship Some 2
Persistent flow of blood into aneurysm sac following endovascular insertion of stent graft (disorder) Finding site Blood vessel structure (body structure) true Inferred relationship Some 1
Persistent flow of blood into aneurysm sac following endovascular insertion of stent graft (disorder) Is a Complication associated with device (disorder) false Inferred relationship Some
Persistent flow of blood into aneurysm sac following endovascular insertion of stent graft (disorder) Associated with Endovascular stent graft (physical object) true Inferred relationship Some 3
Persistent flow of blood into aneurysm sac following endovascular insertion of stent graft (disorder) Is a Complication of implant false Inferred relationship Some
Persistent flow of blood into aneurysm sac following endovascular insertion of stent graft (disorder) Is a Postoperative complication (disorder) true Inferred relationship Some
Persistent flow of blood into aneurysm sac following endovascular insertion of stent graft (disorder) Is a Complication associated with vascular implant true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start