Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
101337013 | Implantation of cardiac dual-chamber device, replacement | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
101339011 | Removal of cardiac pacemaker with replacement by dual-chamber device | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
799997010 | Implantation of cardiac dual-chamber device, replacement (procedure) | en | Fully specified name | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
1576821000052113 | implantation av tvåkammarprodukt, byte | sv | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT Sweden NRC maintained module (core metadata concept) |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Implantation of cardiac dual-chamber device, replacement | Is a | Implantation of heart pacemaker | false | Inferred relationship | Some | ||
Implantation of cardiac dual-chamber device, replacement | Method | Implantation - action | false | Inferred relationship | Some | 2 | |
Implantation of cardiac dual-chamber device, replacement | Procedure site | Heart structure | false | Inferred relationship | Some | 1 | |
Implantation of cardiac dual-chamber device, replacement | Procedure site | Body structure | false | Inferred relationship | Some | 2 | |
Implantation of cardiac dual-chamber device, replacement | Method | Insertion - action (qualifier value) | false | Inferred relationship | Some | 1 | |
Implantation of cardiac dual-chamber device, replacement | Direct device | Cardiac pacemaker | true | Inferred relationship | Some | 1 | |
Implantation of cardiac dual-chamber device, replacement | Method | Insertion - action (qualifier value) | false | Inferred relationship | Some | 2 | |
Implantation of cardiac dual-chamber device, replacement | Is a | Implantation of cardiac pacemaker | false | Inferred relationship | Some | ||
Implantation of cardiac dual-chamber device, replacement | Direct device | Cardiac pacemaker electrode | false | Inferred relationship | Some | 1 | |
Implantation of cardiac dual-chamber device, replacement | Procedure site - Direct (attribute) | Heart structure | false | Inferred relationship | Some | 2 | |
Implantation of cardiac dual-chamber device, replacement | Procedure site - Indirect (attribute) | Heart structure | false | Inferred relationship | Some | 1 | |
Implantation of cardiac dual-chamber device, replacement | Direct device | Cardiac pacemaker | false | Inferred relationship | Some | 1 | |
Implantation of cardiac dual-chamber device, replacement | Procedure site - Indirect (attribute) | Heart structure | true | Inferred relationship | Some | 1 | |
Implantation of cardiac dual-chamber device, replacement | Method | Insertion - action (qualifier value) | false | Inferred relationship | Some | 1 | |
Implantation of cardiac dual-chamber device, replacement | Method | Replacement - action | true | Inferred relationship | Some | 1 | |
Implantation of cardiac dual-chamber device, replacement | Is a | Replacement of cardiac pacemaker (procedure) | true | Inferred relationship | Some |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
Removal of single-chamber cardiac pacemaker with replacement by dual-chamber cardiac pacemaker (procedure) | Is a | True | Implantation of cardiac dual-chamber device, replacement | Inferred relationship | Some |
This concept is not in any reference sets