FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

446815007: Implantation of electrode into brain using stereotactic guidance (procedure)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 28-Feb 2022. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2879850011 Implantation of electrode into brain using stereotactic guidance (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2883664014 Implantation of electrode into brain using stereotactic guidance en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
3514941000052117 implantation av elektrod i hjärnan med stereotaktisk vägledning sv Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Sweden NRC maintained module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Implantation of electrode into brain using stereotactic guidance (procedure) Is a Implantation of electrode into brain true Inferred relationship Some
Implantation of electrode into brain using stereotactic guidance (procedure) Method Insertion - action (qualifier value) false Inferred relationship Some 1
Implantation of electrode into brain using stereotactic guidance (procedure) Direct device Electrode false Inferred relationship Some 1
Implantation of electrode into brain using stereotactic guidance (procedure) Procedure site - Indirect (attribute) Brain structure false Inferred relationship Some 1
Implantation of electrode into brain using stereotactic guidance (procedure) Method Insertion - action (qualifier value) false Inferred relationship Some 1
Implantation of electrode into brain using stereotactic guidance (procedure) Direct device Electrode true Inferred relationship Some 1
Implantation of electrode into brain using stereotactic guidance (procedure) Procedure site - Indirect (attribute) Brain structure true Inferred relationship Some 1
Implantation of electrode into brain using stereotactic guidance (procedure) Method Implantation - action true Inferred relationship Some 1
Implantation of electrode into brain using stereotactic guidance (procedure) Is a Procedure by intent true Inferred relationship Some
Implantation of electrode into brain using stereotactic guidance (procedure) Using device (attribute) Stereotactic device true Inferred relationship Some 2
Implantation of electrode into brain using stereotactic guidance (procedure) Has intent Guidance intent (qualifier value) true Inferred relationship Some 2
Implantation of electrode into brain using stereotactic guidance (procedure) Procedure site - Direct (attribute) Brain structure true Inferred relationship Some 2

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start