FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

432092009: Insertion of cardiac defibrillator using fluoroscopic guidance (procedure)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2008. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2736932010 Insertion of cardiac defibrillator using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2771956016 Insertion of cardiac defibrillator using fluoroscopic guidance en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
2021791000052111 inläggning av defibrillator under röntgengenomlysning sv Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Sweden NRC maintained module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Insertion of cardiac defibrillator using fluoroscopic guidance (procedure) Is a Cardiac fluoroscopy true Inferred relationship Some
Insertion of cardiac defibrillator using fluoroscopic guidance (procedure) Is a Insertion using fluoroscopic guidance (procedure) true Inferred relationship Some
Insertion of cardiac defibrillator using fluoroscopic guidance (procedure) Is a Implantation of automatic cardiac defibrillator false Inferred relationship Some
Insertion of cardiac defibrillator using fluoroscopic guidance (procedure) Method Fluoroscopic imaging - action (qualifier value) false Inferred relationship Some 1
Insertion of cardiac defibrillator using fluoroscopic guidance (procedure) Procedure site - Direct (attribute) Heart structure false Inferred relationship Some 1
Insertion of cardiac defibrillator using fluoroscopic guidance (procedure) Method Insertion - action (qualifier value) false Inferred relationship Some 2
Insertion of cardiac defibrillator using fluoroscopic guidance (procedure) Direct device Automatic cardiac defibrillator false Inferred relationship Some 2
Insertion of cardiac defibrillator using fluoroscopic guidance (procedure) Has intent Guidance intent (qualifier value) false Inferred relationship Some 1
Insertion of cardiac defibrillator using fluoroscopic guidance (procedure) Procedure site - Indirect (attribute) Heart structure false Inferred relationship Some 2
Insertion of cardiac defibrillator using fluoroscopic guidance (procedure) Procedure site - Direct (attribute) Heart structure true Inferred relationship Some 1
Insertion of cardiac defibrillator using fluoroscopic guidance (procedure) Method Fluoroscopic imaging - action (qualifier value) true Inferred relationship Some 1
Insertion of cardiac defibrillator using fluoroscopic guidance (procedure) Method Insertion - action (qualifier value) true Inferred relationship Some 2
Insertion of cardiac defibrillator using fluoroscopic guidance (procedure) Direct device Automatic cardiac defibrillator true Inferred relationship Some 2
Insertion of cardiac defibrillator using fluoroscopic guidance (procedure) Has intent Guidance intent (qualifier value) true Inferred relationship Some 1
Insertion of cardiac defibrillator using fluoroscopic guidance (procedure) Procedure site - Indirect (attribute) Heart structure true Inferred relationship Some 2
Insertion of cardiac defibrillator using fluoroscopic guidance (procedure) Is a Automatic defibrillator procedure true Inferred relationship Some
Insertion of cardiac defibrillator using fluoroscopic guidance (procedure) Is a Biomedical equipment procedure (procedure) true Inferred relationship Some
Insertion of cardiac defibrillator using fluoroscopic guidance (procedure) Is a Implantation of automatic cardiac defibrillator and/or cardiac pacemaker and/or ventricular assist device true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Is a False Insertion of cardiac defibrillator using fluoroscopic guidance (procedure) Inferred relationship Some

This concept is not in any reference sets