FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

311464004: Internal fixation using wire (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
455039015 Internal fixation using wire en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
708022016 Internal fixation using wire (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2139391000052118 intern fixering med ståltråd sv Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Sweden NRC maintained module (core metadata concept)


3 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Internal fixation using wire Is a Introduction procedure (procedure) false Inferred relationship Some
Internal fixation using wire Is a Internal skeletal fixation false Inferred relationship Some
Internal fixation using wire Is a Equipment-related procedure false Inferred relationship Some
Internal fixation using wire Procedure site Bone structure false Inferred relationship Some 1
Internal fixation using wire Direct device Bone wire false Inferred relationship Some 1
Internal fixation using wire Procedure site Skeletal system structure false Inferred relationship Some
Internal fixation using wire Method Implantation - action false Inferred relationship Some 2
Internal fixation using wire Access Open approach false Inferred relationship Some 1
Internal fixation using wire Is a implantation i muskuloskeletala systemet false Inferred relationship Some
Internal fixation using wire Method Fixation - action false Inferred relationship Some 1
Internal fixation using wire Method Insertion - action (qualifier value) false Inferred relationship Some 1
Internal fixation using wire Procedure site Bone structure false Inferred relationship Some 2
Internal fixation using wire Procedure site Bone structure false Inferred relationship Some 2
Internal fixation using wire Is a åtgärd, indelning efter utrustning false Inferred relationship Some
Internal fixation using wire Using Orthopedic internal fixation system false Inferred relationship Some 2
Internal fixation using wire Procedure site Bone structure false Inferred relationship Some 1
Internal fixation using wire Procedure site Bone structure false Inferred relationship Some 2
Internal fixation using wire Procedure site - Indirect (attribute) Bone structure false Inferred relationship Some 1
Internal fixation using wire Direct morphology Fracture false Inferred relationship Some 1
Internal fixation using wire Is a Fixation of fracture using wire true Inferred relationship Some
Internal fixation using wire Using device (attribute) Bone wire false Inferred relationship Some 1
Internal fixation using wire Procedure site - Direct (attribute) Bone structure false Inferred relationship Some 1
Internal fixation using wire Access Open approach true Inferred relationship Some 1
Internal fixation using wire Procedure site - Direct (attribute) Bone structure true Inferred relationship Some 1
Internal fixation using wire Direct morphology Fracture true Inferred relationship Some 1
Internal fixation using wire Method Fixation - action true Inferred relationship Some 1
Internal fixation using wire Using device (attribute) Bone wire true Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group
Internal fixation using Kirschner wire Is a True Internal fixation using wire Inferred relationship Some
Internal fixation using tension band Is a True Internal fixation using wire Inferred relationship Some

This concept is not in any reference sets

Back to Start