FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

444437006: Insertion of transvenous electrode of dual chamber pacing cardioverter defibrillator pulse generator (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2010. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2835798014 Insertion of transvenous electrode of dual chamber pacing cardioverter defibrillator pulse generator (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2840252014 Insertion of transvenous electrode of dual chamber pacing cardioverter defibrillator pulse generator en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
3248901000052114 inläggning av transvenös elektrod för pulsgenerator hos tvåkammarpacemaker med defibrillator sv Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Sweden NRC maintained module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Insertion of transvenous electrode of dual chamber pacing cardioverter defibrillator pulse generator (procedure) Is a Insertion of dual chamber cardiac pacemaker pulse generator (procedure) true Inferred relationship Some
Insertion of transvenous electrode of dual chamber pacing cardioverter defibrillator pulse generator (procedure) Method Insertion - action (qualifier value) true Inferred relationship Some 2
Insertion of transvenous electrode of dual chamber pacing cardioverter defibrillator pulse generator (procedure) Direct device Transvenous electrode true Inferred relationship Some 2
Insertion of transvenous electrode of dual chamber pacing cardioverter defibrillator pulse generator (procedure) Method Insertion - action (qualifier value) true Inferred relationship Some 1
Insertion of transvenous electrode of dual chamber pacing cardioverter defibrillator pulse generator (procedure) Direct device Dual chamber pacing cardioverter defibrillator pulse generator, device (physical object) true Inferred relationship Some 1
Insertion of transvenous electrode of dual chamber pacing cardioverter defibrillator pulse generator (procedure) Method Insertion - action (qualifier value) false Inferred relationship Some 3
Insertion of transvenous electrode of dual chamber pacing cardioverter defibrillator pulse generator (procedure) Direct device Biomedical device false Inferred relationship Some 3

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start