FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.12  |  FHIR Version n/a  User: [n/a]

443676006: Surgical removal of transvenous electrode of single chamber pacing cardioverter defibrillator pulse generator by transthoracic approach (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2010. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2837082010 Surgical removal of transvenous electrode of single chamber pacing cardioverter defibrillator pulse generator by transthoracic approach (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2841086017 Surgical removal of transvenous electrode of single chamber pacing cardioverter defibrillator pulse generator by transthoracic approach en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
3248841000052118 kirurgiskt avlägsnande av transvenös elektrod tillhörande pulsgenerator i enkammarpacemaker med defibrillator via transtorakal åtkomst sv Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Sweden NRC maintained module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Surgical removal of transvenous electrode of single chamber pacing cardioverter defibrillator pulse generator by transthoracic approach (procedure) Is a Removal of transvenous electrodes true Inferred relationship Some
Surgical removal of transvenous electrode of single chamber pacing cardioverter defibrillator pulse generator by transthoracic approach (procedure) Is a Removal of implant false Inferred relationship Some
Surgical removal of transvenous electrode of single chamber pacing cardioverter defibrillator pulse generator by transthoracic approach (procedure) Is a Operation on heart true Inferred relationship Some
Surgical removal of transvenous electrode of single chamber pacing cardioverter defibrillator pulse generator by transthoracic approach (procedure) Procedure site - Indirect (attribute) Heart structure false Inferred relationship Some 1
Surgical removal of transvenous electrode of single chamber pacing cardioverter defibrillator pulse generator by transthoracic approach (procedure) Method Surgical removal - action false Inferred relationship Some 1
Surgical removal of transvenous electrode of single chamber pacing cardioverter defibrillator pulse generator by transthoracic approach (procedure) Direct device Transvenous electrode false Inferred relationship Some 1
Surgical removal of transvenous electrode of single chamber pacing cardioverter defibrillator pulse generator by transthoracic approach (procedure) Surgical approach (attribute) Transthoracic approach false Inferred relationship Some 1
Surgical removal of transvenous electrode of single chamber pacing cardioverter defibrillator pulse generator by transthoracic approach (procedure) Direct device Transvenous electrode true Inferred relationship Some 1
Surgical removal of transvenous electrode of single chamber pacing cardioverter defibrillator pulse generator by transthoracic approach (procedure) Surgical approach (attribute) Transthoracic approach true Inferred relationship Some 1
Surgical removal of transvenous electrode of single chamber pacing cardioverter defibrillator pulse generator by transthoracic approach (procedure) Method Surgical removal - action true Inferred relationship Some 1
Surgical removal of transvenous electrode of single chamber pacing cardioverter defibrillator pulse generator by transthoracic approach (procedure) Procedure site - Indirect (attribute) Heart structure true Inferred relationship Some 1
Surgical removal of transvenous electrode of single chamber pacing cardioverter defibrillator pulse generator by transthoracic approach (procedure) Is a Operations by approach true Inferred relationship Some
Surgical removal of transvenous electrode of single chamber pacing cardioverter defibrillator pulse generator by transthoracic approach (procedure) Is a Surgical removal true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start