Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
457218015 | Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
710100015 | Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw (procedure) | en | Fully specified name | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
2193771000052113 | sluten reposition av intrakapsulär fraktur på collum femoris och intern fixering med användning av dynamisk höftskruv | sv | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT Sweden NRC maintained module (core metadata concept) |
4994811000052116 | sluten reponering av intrakapsulär fraktur på collum femoris och intern fixering med användning av dynamisk höftskruv | sv | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT Sweden NRC maintained module (core metadata concept) |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Is a | operativ åtgärd på bäckenet | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Is a | Fixation of fracture using dynamic compression system | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Is a | Operation on hip joint | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Is a | Procedure on thigh | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Procedure site | Bone structure | false | Inferred relationship | Some | 1 | |
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Method | Implantation - action | false | Inferred relationship | Some | 2 | |
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Access | Open approach | false | Inferred relationship | Some | 1 | |
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Procedure site | Structure of neck of femur | false | Inferred relationship | Some | 2 | |
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Method | Fixation - action | true | Inferred relationship | Some | 2 | |
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Is a | Operation on trunk | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Is a | implantation i höftled | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Is a | implantation i lår | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Is a | Procedure on femur | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Is a | Reduction of fracture | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Method | Reduction - action | false | Inferred relationship | Some | 1 | |
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Direct morphology | Fracture | false | Inferred relationship | Some | 1 | |
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Is a | Procedure on hip joint | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Is a | Open reduction of fracture with internal fixation | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Direct device | Orthopedic internal fixation system | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Is a | Open reduction of fracture with fixation | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Using | Orthopedic internal fixation system | false | Inferred relationship | Some | 1 | |
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Is a | Reduction procedure | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Is a | Open reduction with internal fixation | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Procedure site - Indirect (attribute) | Bone structure | false | Inferred relationship | Some | 1 | |
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Direct device | Orthopedic internal fixation system | false | Inferred relationship | Some | 1 | |
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Is a | Open reduction | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Procedure site - Direct (attribute) | Structure of neck of femur | false | Inferred relationship | Some | 1 | |
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Using device (attribute) | Orthopedic internal fixation system | false | Inferred relationship | Some | 2 | |
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Procedure site - Direct (attribute) | Bone structure | false | Inferred relationship | Some | 2 | |
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Using device (attribute) | Bone screw | true | Inferred relationship | Some | 2 | |
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Direct morphology | Fracture | false | Inferred relationship | Some | 1 | |
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Direct morphology | Fracture | false | Inferred relationship | Some | 2 | |
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Is a | Fixation of hip | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Is a | Closed reduction of fracture of femur with internal fixation | true | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Is a | Closed reduction of fracture of hip | true | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Is a | Fixation of fracture using screws | true | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Method | Closed reduction - action (qualifier value) | true | Inferred relationship | Some | 1 | |
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Direct morphology | Fracture | true | Inferred relationship | Some | 1 | |
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Direct morphology | Fracture | true | Inferred relationship | Some | 2 | |
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Procedure site - Direct (attribute) | Structure of neck of femur | true | Inferred relationship | Some | 1 | |
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Procedure site - Direct (attribute) | Structure of neck of femur | true | Inferred relationship | Some | 2 | |
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | Is a | Operative procedure on hip (procedure) | true | Inferred relationship | Some |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
This concept is not in any reference sets