FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

1153380009: Mechanical hemolysis following insertion of prosthetic heart valve (disorder)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2021. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
4564168019 Mechanical haemolysis due to prosthetic valve en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
4564169010 Mechanical hemolysis following insertion of prosthetic heart valve (disorder) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
4564170011 Mechanical hemolysis following insertion of prosthetic heart valve en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
5094101000052111 mekanisk hemolys efter inläggning av hjärtklaffprotes sv Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Sweden NRC maintained module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Mechanical haemolysis due to prosthetic valve Interprets Red blood cell count true Inferred relationship Some 2
Mechanical haemolysis due to prosthetic valve Has interpretation Below reference range true Inferred relationship Some 4
Mechanical haemolysis due to prosthetic valve Has interpretation Present true Inferred relationship Some 3
Mechanical haemolysis due to prosthetic valve Interprets Hemolysis (observable entity) true Inferred relationship Some 3
Mechanical haemolysis due to prosthetic valve Is a Traumatic cardiac hemolytic anemia true Inferred relationship Some
Mechanical haemolysis due to prosthetic valve Has interpretation Below reference range true Inferred relationship Some 2
Mechanical haemolysis due to prosthetic valve Finding site Erythrocyte true Inferred relationship Some 5
Mechanical haemolysis due to prosthetic valve Is a Postoperative complication (disorder) true Inferred relationship Some
Mechanical haemolysis due to prosthetic valve Interprets Measurement of total haemoglobin concentration true Inferred relationship Some 4
Mechanical haemolysis due to prosthetic valve After Prosthetic replacement of heart valve (procedure) true Inferred relationship Some 1
Mechanical haemolysis due to prosthetic valve Is a Hemoglobin low true Inferred relationship Some
Mechanical haemolysis due to prosthetic valve Is a Red blood cell disorder true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start