FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.24  |  FHIR Version n/a  User: [n/a]

8069005: Implantation of tricuspid valve prosthesis or synthetic device (procedure)


Status: current, Primitive. Date: 31-Oct 2021. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
14330017 Implantation of tricuspid valve prosthesis or synthetic device en Synonym Active Case insensitive SNOMED CT core
821878015 Implantation of tricuspid valve prosthesis or synthetic device (procedure) en Fully specified name Active Case insensitive SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Implantation of tricuspid valve prosthesis or synthetic device Method Implantation - action false Inferred relationship Some 1
Implantation of tricuspid valve prosthesis or synthetic device Method Surgical implantation - action true Inferred relationship Some 1
Implantation of tricuspid valve prosthesis or synthetic device Procedure site - Direct Tricuspid valve structure true Inferred relationship Some 1
Implantation of tricuspid valve prosthesis or synthetic device Direct device Tricuspid valve prosthesis true Inferred relationship Some 1
Implantation of tricuspid valve prosthesis or synthetic device Procedure site Cardiac valve structure false Inferred relationship Some 3
Implantation of tricuspid valve prosthesis or synthetic device Procedure site Body structure false Inferred relationship Some 2
Implantation of tricuspid valve prosthesis or synthetic device Method Insertion - action false Inferred relationship Some 1
Implantation of tricuspid valve prosthesis or synthetic device Direct device Implant false Inferred relationship Some
Implantation of tricuspid valve prosthesis or synthetic device Is a Tricuspid valve operation true Inferred relationship Some
Implantation of tricuspid valve prosthesis or synthetic device Is a Implantation of heart valve prosthesis or synthetic device true Inferred relationship Some
Implantation of tricuspid valve prosthesis or synthetic device Direct device Cardiac valve prosthesis false Inferred relationship Some 1
Implantation of tricuspid valve prosthesis or synthetic device Procedure site - Indirect Tricuspid valve structure false Inferred relationship Some 1
Implantation of tricuspid valve prosthesis or synthetic device Direct device Cardiac valve prosthesis false Inferred relationship Some 1
Implantation of tricuspid valve prosthesis or synthetic device Procedure site - Indirect Tricuspid valve structure false Inferred relationship Some 1
Implantation of tricuspid valve prosthesis or synthetic device Method Insertion - action false Inferred relationship Some 1
Implantation of tricuspid valve prosthesis or synthetic device Is a Operation on implanted tricuspid valve false Inferred relationship Some
Implantation of tricuspid valve prosthesis or synthetic device Procedure site - Indirect Tricuspid valve structure false Inferred relationship Some 2
Implantation of tricuspid valve prosthesis or synthetic device Method Surgical insertion - action false Inferred relationship Some 2
Implantation of tricuspid valve prosthesis or synthetic device Direct device Cardiac valve prosthesis false Inferred relationship Some 2
Implantation of tricuspid valve prosthesis or synthetic device Method Surgical action false Inferred relationship Some 3
Implantation of tricuspid valve prosthesis or synthetic device Method Implantation - action false Inferred relationship Some 2
Implantation of tricuspid valve prosthesis or synthetic device Procedure site Tricuspid valve structure false Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group
Endocarditis of prosthetic tricuspid valve Following True Implantation of tricuspid valve prosthesis or synthetic device Inferred relationship Some 2
Prosthetic tricuspid valve regurgitation Following True Implantation of tricuspid valve prosthesis or synthetic device Inferred relationship Some 2
Acute prosthetic tricuspid valve regurgitation Following True Implantation of tricuspid valve prosthesis or synthetic device Inferred relationship Some 2
Prosthetic tricuspid valve failure Following True Implantation of tricuspid valve prosthesis or synthetic device Inferred relationship Some 3
Prosthetic tricuspid valve failure requiring revision Following True Implantation of tricuspid valve prosthesis or synthetic device Inferred relationship Some 1
Prosthetic tricuspid valve failure requiring replacement Following True Implantation of tricuspid valve prosthesis or synthetic device Inferred relationship Some 1
Prosthetic tricuspid valve stenosis Following True Implantation of tricuspid valve prosthesis or synthetic device Inferred relationship Some 2
Disorder of tricuspid valve prosthesis Following True Implantation of tricuspid valve prosthesis or synthetic device Inferred relationship Some 2
Implantation of tricuspid valve with tissue graft Is a False Implantation of tricuspid valve prosthesis or synthetic device Inferred relationship Some

Reference Sets

Royal Australasian College of Surgeons MALT surgical procedure reference set

Procedure foundation reference set

Back to Start