FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

706004007: Implantable cardiac pacemaker (physical object)


Status: current, Primitive. Date: 31-Jul 2014. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
3025217018 Implantable cardiac pacemaker en Synonym Active Case insensitive SNOMED CT core
3025218011 Implantable cardiac pacemaker (physical object) en Fully specified name Active Case insensitive SNOMED CT core


7 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Implantable cardiac pacemaker Is a Implant true Inferred relationship Some
Implantable cardiac pacemaker Is a Cardiac pacemaker true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group
Leadless implantable cardiac pacemaker Is a True Implantable cardiac pacemaker Inferred relationship Some
Malfunction of biventricular cardiac pacemaker Associated with True Implantable cardiac pacemaker Inferred relationship Some 2
Malfunction of biventricular cardiac pacemaker battery Associated with True Implantable cardiac pacemaker Inferred relationship Some 2
Protrusion of cardiac device Associated with True Implantable cardiac pacemaker Inferred relationship Some 2
Stimulation of muscle pocket due to and after implantation of cardiac pacemaker Associated with True Implantable cardiac pacemaker Inferred relationship Some 4
Infected pacemaker Associated with True Implantable cardiac pacemaker Inferred relationship Some 2
Infection of biventricular cardiac pacemaker Associated with True Implantable cardiac pacemaker Inferred relationship Some 2
Cross-talk in dual chamber cardiac pacemaker Associated with True Implantable cardiac pacemaker Inferred relationship Some 1
Stimulation of phrenic nerve due to and after implantation of cardiac pacemaker Associated with True Implantable cardiac pacemaker Inferred relationship Some 4
Infection of pacemaker pulse generator site Associated with True Implantable cardiac pacemaker Inferred relationship Some 3
Pacemaker electrode infection Associated with True Implantable cardiac pacemaker Inferred relationship Some 2
Erosion of pacemaker pocket due to and following implantation of cardiac pacemaker Associated with True Implantable cardiac pacemaker Inferred relationship Some 4
Cardiac resynchronisation therapy implantable pacemaker Is a True Implantable cardiac pacemaker Inferred relationship Some
Dual chamber demand implantable cardiac pacemaker Is a True Implantable cardiac pacemaker Inferred relationship Some
Dual chamber rate responsive implantable cardiac pacemaker Is a True Implantable cardiac pacemaker Inferred relationship Some
Intracardiac pacemaker Is a True Implantable cardiac pacemaker Inferred relationship Some
Single chamber fixed rate and/or demand implantable cardiac pacemaker Is a True Implantable cardiac pacemaker Inferred relationship Some
Single chamber rate responsive implantable cardiac pacemaker Is a True Implantable cardiac pacemaker Inferred relationship Some
Removal of implantable cardiac pacemaker Direct device True Implantable cardiac pacemaker Inferred relationship Some 1

Reference Sets

Physical object foundation reference set

Back to Start