FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.8.2  |  FHIR Version n/a  User: [n/a]

705963005: Hemodynamic measuring device (physical object)


Status: current, Primitive. Date: 31-Jul 2014. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
3025136018 Haemodynamic measuring device en Synonym Active Case insensitive SNOMED CT core
3027042015 Hemodynamic measuring device en Synonym Active Case insensitive SNOMED CT core
3027043013 Hemodynamic measuring device (physical object) en Fully specified name Active Case insensitive SNOMED CT core


29 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Haemodynamic measuring device Is a Cardiovascular equipment true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group
Device associated with blood flowmeters Is a False Haemodynamic measuring device Inferred relationship Some
Device associated with cardiac output units Is a False Haemodynamic measuring device Inferred relationship Some
Blood pressure alarm Is a False Haemodynamic measuring device Inferred relationship Some
Arterial blood pressure catheter Is a False Haemodynamic measuring device Inferred relationship Some
Cardiac catheterisation laboratory computer Is a False Haemodynamic measuring device Inferred relationship Some
Blood pressure long-term ambulatory recorder Is a False Haemodynamic measuring device Inferred relationship Some
Neonatal physiologic monitoring system Is a True Haemodynamic measuring device Inferred relationship Some
Transportable physiologic monitoring system Is a True Haemodynamic measuring device Inferred relationship Some
Ocular plethysmograph Is a False Haemodynamic measuring device Inferred relationship Some
Venous pressure monitor Is a True Haemodynamic measuring device Inferred relationship Some
Noninvasive blood pressure simulator Is a False Haemodynamic measuring device Inferred relationship Some
Ultrasonic stethoscope Is a True Haemodynamic measuring device Inferred relationship Some
Blood pressure transducer, reusable Is a False Haemodynamic measuring device Inferred relationship Some
Blood pressure transducer, single-use Is a False Haemodynamic measuring device Inferred relationship Some
Pressure transducer dome, reusable Is a False Haemodynamic measuring device Inferred relationship Some
Pressure transducer dome, single-use Is a False Haemodynamic measuring device Inferred relationship Some
Blood pressure transducer holder Is a False Haemodynamic measuring device Inferred relationship Some
Ploss valve Is a False Haemodynamic measuring device Inferred relationship Some
Peripheral vascular infusion/aspiration catheter, antimicrobial Is a False Haemodynamic measuring device Inferred relationship Some
Cardiovascular-risk peripheral arterial tonometry system Is a True Haemodynamic measuring device Inferred relationship Some
Cardiac catheterisation mobile medical facility Is a False Haemodynamic measuring device Inferred relationship Some
Cardiovascular-risk peripheral arterial tonometry system application software Is a False Haemodynamic measuring device Inferred relationship Some
Cardiovascular-risk peripheral arterial tonometry system data processor Is a False Haemodynamic measuring device Inferred relationship Some
Blood pressure transducer set Is a False Haemodynamic measuring device Inferred relationship Some
Physiology-monitoring sedation system Is a False Haemodynamic measuring device Inferred relationship Some
Invasive blood pressure simulator Is a False Haemodynamic measuring device Inferred relationship Some
Invasive blood pressure transducer simulator Is a False Haemodynamic measuring device Inferred relationship Some
Multiple physiological parameter spot-check analysis system, home-use Is a True Haemodynamic measuring device Inferred relationship Some
Multiple physiological parameter spot-check analysis system, clinical Is a True Haemodynamic measuring device Inferred relationship Some
Multi-patient physiologic monitoring system Is a False Haemodynamic measuring device Inferred relationship Some
Single-patient physiologic monitoring system Is a False Haemodynamic measuring device Inferred relationship Some
Intravascular haemodynamic monitoring system Is a True Haemodynamic measuring device Inferred relationship Some
Intravascular haemodynamic monitoring system guidewire Is a True Haemodynamic measuring device Inferred relationship Some
Single-patient physiologic monitoring system application software Is a False Haemodynamic measuring device Inferred relationship Some
Vascular Doppler system Is a True Haemodynamic measuring device Inferred relationship Some
Ballistocardiograph Is a True Haemodynamic measuring device Inferred relationship Some
Blood flowmeter Is a True Haemodynamic measuring device Inferred relationship Some
Cardiac output unit Is a True Haemodynamic measuring device Inferred relationship Some
Thermal-dilution cardiac output unit Is a True Haemodynamic measuring device Inferred relationship Some
Noninvasive hemodynamic monitor Is a True Haemodynamic measuring device Inferred relationship Some
Injectate temperature probe Is a True Haemodynamic measuring device Inferred relationship Some
ECG modulated activator Is a True Haemodynamic measuring device Inferred relationship Some
Breast 3-D infrared imaging/vascular analysis system Is a True Haemodynamic measuring device Inferred relationship Some

Reference Sets

Physical object foundation reference set

Back to Start