FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

54303005: Posterior spinal instrumentation with segmental fixation (procedure)


Status: current, Primitive. Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
792520013 Posterior spinal instrumentation with segmental fixation (procedure) en Fully specified name Active Case insensitive SNOMED CT core
90262019 Posterior spinal instrumentation with segmental fixation en Synonym Active Case insensitive SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Posterior spinal instrumentation with segmental fixation Is a Insertion procedure true Inferred relationship Some
Posterior spinal instrumentation with segmental fixation Is a Anterior spinal instrumentation false Inferred relationship Some
Posterior spinal instrumentation with segmental fixation Method Surgical action false Inferred relationship Some 4
Posterior spinal instrumentation with segmental fixation Method Fixation - action false Inferred relationship Some 1
Posterior spinal instrumentation with segmental fixation Procedure site Bone structure false Inferred relationship Some 1
Posterior spinal instrumentation with segmental fixation Method Insertion - action false Inferred relationship Some 2
Posterior spinal instrumentation with segmental fixation Direct device Orthopaedic internal fixation system false Inferred relationship Some 2
Posterior spinal instrumentation with segmental fixation Direct device Surgical instrument false Inferred relationship Some
Posterior spinal instrumentation with segmental fixation Using Orthopaedic internal fixation system false Inferred relationship Some 1
Posterior spinal instrumentation with segmental fixation Is a Musculoskeletal system implantation false Inferred relationship Some
Posterior spinal instrumentation with segmental fixation Is a Implantation of spine false Inferred relationship Some
Posterior spinal instrumentation with segmental fixation Is a Posterior spinal instrumentation true Inferred relationship Some
Posterior spinal instrumentation with segmental fixation Is a Internal skeletal fixation false Inferred relationship Some
Posterior spinal instrumentation with segmental fixation Using Surgical instrument false Inferred relationship Some
Posterior spinal instrumentation with segmental fixation Direct morphology Fracture false Inferred relationship Some 1
Posterior spinal instrumentation with segmental fixation Procedure site - Indirect Bone structure false Inferred relationship Some 1
Posterior spinal instrumentation with segmental fixation Is a Procedure by approach false Inferred relationship Some
Posterior spinal instrumentation with segmental fixation Is a Musculoskeletal system implantation false Inferred relationship Some
Posterior spinal instrumentation with segmental fixation Is a Implantation of prosthetic device false Inferred relationship Some
Posterior spinal instrumentation with segmental fixation Is a Operation on vertebra false Inferred relationship Some
Posterior spinal instrumentation with segmental fixation Is a Implantation of spine false Inferred relationship Some
Posterior spinal instrumentation with segmental fixation Using device Orthopaedic internal fixation system false Inferred relationship Some 3
Posterior spinal instrumentation with segmental fixation Using device Surgical instrument false Inferred relationship Some 4
Posterior spinal instrumentation with segmental fixation Approach Posterior spinal approach false Inferred relationship Some 2
Posterior spinal instrumentation with segmental fixation Approach Posterior spinal approach false Inferred relationship Some 1
Posterior spinal instrumentation with segmental fixation Procedure site - Indirect Bone structure of spine false Inferred relationship Some 2
Posterior spinal instrumentation with segmental fixation Procedure site - Direct Bone structure of spine false Inferred relationship Some 1
Posterior spinal instrumentation with segmental fixation Procedure site - Direct Spinal structure false Inferred relationship Some 4
Posterior spinal instrumentation with segmental fixation Procedure site - Direct Bone structure false Inferred relationship Some 3
Posterior spinal instrumentation with segmental fixation Method Fixation - action false Inferred relationship Some 1
Posterior spinal instrumentation with segmental fixation Method Fixation - action false Inferred relationship Some 3
Posterior spinal instrumentation with segmental fixation Is a Insertion of therapeutic device false Inferred relationship Some
Posterior spinal instrumentation with segmental fixation Surgical approach Posterior spinal approach false Inferred relationship Some 1
Posterior spinal instrumentation with segmental fixation Procedure site - Indirect Bone structure of spine false Inferred relationship Some 1
Posterior spinal instrumentation with segmental fixation Method Fixation - action false Inferred relationship Some 1
Posterior spinal instrumentation with segmental fixation Procedure site - Direct Bone structure of spine false Inferred relationship Some 1
Posterior spinal instrumentation with segmental fixation Method Insertion - action false Inferred relationship Some 1
Posterior spinal instrumentation with segmental fixation Direct device Orthopaedic internal fixation system false Inferred relationship Some 1
Posterior spinal instrumentation with segmental fixation Surgical approach Posterior spinal approach false Inferred relationship Some 1
Posterior spinal instrumentation with segmental fixation Using device Orthopaedic internal fixation system false Inferred relationship Some 2
Posterior spinal instrumentation with segmental fixation Method Fixation - action false Inferred relationship Some 2
Posterior spinal instrumentation with segmental fixation Procedure site - Direct Bone structure of spine false Inferred relationship Some 2
Posterior spinal instrumentation with segmental fixation Surgical approach Posterior approach false Inferred relationship Some 2
Posterior spinal instrumentation with segmental fixation Surgical approach Posterior approach true Inferred relationship Some 2
Posterior spinal instrumentation with segmental fixation Method Fixation - action true Inferred relationship Some 2
Posterior spinal instrumentation with segmental fixation Using device Orthopaedic internal fixation system true Inferred relationship Some 2
Posterior spinal instrumentation with segmental fixation Procedure site - Direct Bone structure of spine true Inferred relationship Some 2
Posterior spinal instrumentation with segmental fixation Surgical approach Posterior spinal approach true Inferred relationship Some 1
Posterior spinal instrumentation with segmental fixation Method Insertion - action true Inferred relationship Some 1
Posterior spinal instrumentation with segmental fixation Direct device Orthopaedic internal fixation system true Inferred relationship Some 1
Posterior spinal instrumentation with segmental fixation Procedure site - Indirect Bone structure of spine true Inferred relationship Some 1
Posterior spinal instrumentation with segmental fixation Method Implantation - action false Inferred relationship Some 1
Posterior spinal instrumentation with segmental fixation Procedure site Spinal structure false Inferred relationship Some 1
Posterior spinal instrumentation with segmental fixation Using Orthopaedic internal fixation system false Inferred relationship Some
Posterior spinal instrumentation with segmental fixation Access Open approach false Inferred relationship Some
Posterior spinal instrumentation with segmental fixation Procedure site Bone structure of spine false Inferred relationship Some 2

Inbound Relationships Type Active Source Characteristic Refinability Group

Reference Sets

Royal Australasian College of Surgeons MALT surgical procedure reference set

Procedure foundation reference set

Back to Start