FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.8.2  |  FHIR Version n/a  User: [n/a]

46825001: Electrocardiographic monitoring (procedure)


Status: current, Defined. Date: 31-Jan 2011. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
3890764015 ECG (electrocardiography) monitoring en Synonym Active Case sensitive SNOMED CT core
78049019 Electrocardiographic monitoring en Synonym Active Case insensitive SNOMED CT core
78052010 Cardiovascular monitoring by ECG en Synonym Active Initial character case insensitive SNOMED CT core
784216010 Electrocardiographic monitoring (procedure) en Fully specified name Active Case insensitive SNOMED CT core


44 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Cardiovascular monitoring by ECG Is a Cardiac monitoring false Inferred relationship Some
Cardiovascular monitoring by ECG Direct device ECG monitor and recorder false Inferred relationship Some
Cardiovascular monitoring by ECG Is a Cardiovascular monitoring false Inferred relationship Some
Cardiovascular monitoring by ECG Is a Cardiac function testing false Inferred relationship Some
Cardiovascular monitoring by ECG Is a ECG procedure true Inferred relationship Some
Cardiovascular monitoring by ECG Using ECG monitor and recorder false Inferred relationship Some 1
Cardiovascular monitoring by ECG Method Monitoring - action false Inferred relationship Some 1
Cardiovascular monitoring by ECG Procedure site Structure of cardiovascular system false Inferred relationship Some 1
Cardiovascular monitoring by ECG Procedure site Structure of cardiovascular system false Inferred relationship Some 2
Cardiovascular monitoring by ECG Procedure site Structure of cardiovascular system false Inferred relationship Some 1
Cardiovascular monitoring by ECG Procedure site Structure of cardiovascular system false Inferred relationship Some 2
Cardiovascular monitoring by ECG Procedure site Structure of cardiovascular system false Inferred relationship Some 1
Cardiovascular monitoring by ECG Procedure site Structure of cardiovascular system false Inferred relationship Some 2
Cardiovascular monitoring by ECG Procedure site Structure of cardiovascular system false Inferred relationship Some 1
Cardiovascular monitoring by ECG Procedure site Structure of cardiovascular system false Inferred relationship Some 2
Cardiovascular monitoring by ECG Procedure site Structure of cardiovascular system false Inferred relationship Some 1
Cardiovascular monitoring by ECG Procedure site Structure of cardiovascular system false Inferred relationship Some 2
Cardiovascular monitoring by ECG Using device ECG monitor and recorder false Inferred relationship Some 1
Cardiovascular monitoring by ECG Procedure site - Direct Structure of cardiovascular system false Inferred relationship Some 1
Cardiovascular monitoring by ECG Method Monitoring - action false Inferred relationship Some 1
Cardiovascular monitoring by ECG Procedure site - Direct Structure of heart false Inferred relationship Some 1
Cardiovascular monitoring by ECG Using device ECG monitor and recorder false Inferred relationship Some 1
Cardiovascular monitoring by ECG Method Monitoring - action true Inferred relationship Some 1
Cardiovascular monitoring by ECG Using device ECG monitor and recorder true Inferred relationship Some 1
Cardiovascular monitoring by ECG Procedure site - Direct Structure of heart true Inferred relationship Some 1
Cardiovascular monitoring by ECG Procedure site Structure of cardiovascular system false Inferred relationship Some
Cardiovascular monitoring by ECG Method Measurement - action false Inferred relationship Some
Cardiovascular monitoring by ECG Method Investigation - action false Inferred relationship Some
Cardiovascular monitoring by ECG Using ECG monitor and recorder false Inferred relationship Some
Cardiovascular monitoring by ECG Has intent Diagnostic intent false Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group
ECG ST segment monitoring Is a True Cardiovascular monitoring by ECG Inferred relationship Some
ECG automated dysrhythmia monitoring Is a True Cardiovascular monitoring by ECG Inferred relationship Some
Single lead ECG Is a True Cardiovascular monitoring by ECG Inferred relationship Some
Stimulation of carotid sinus with ECG monitoring Is a True Cardiovascular monitoring by ECG Inferred relationship Some
Bundle of His recording Is a False Cardiovascular monitoring by ECG Inferred relationship Some
Monitoring of cardiac output by ECG Is a True Cardiovascular monitoring by ECG Inferred relationship Some
Signal-averaged electrocardiography Is a True Cardiovascular monitoring by ECG Inferred relationship Some
ECG monitoring, 10 hour portrait Is a True Cardiovascular monitoring by ECG Inferred relationship Some
Electrocardiogram with exercise test Is a True Cardiovascular monitoring by ECG Inferred relationship Some
Electrocardiogram, esophageal lead Is a True Cardiovascular monitoring by ECG Inferred relationship Some
Intracardiac ECG Is a True Cardiovascular monitoring by ECG Inferred relationship Some
ECG recording from artificial pacemaker Is a True Cardiovascular monitoring by ECG Inferred relationship Some
Rhythm ECG Is a True Cardiovascular monitoring by ECG Inferred relationship Some
ECG with vectorcardiogram Is a True Cardiovascular monitoring by ECG Inferred relationship Some
Monitoring of ECG, pressure, blood gases and cardiac output Is a True Cardiovascular monitoring by ECG Inferred relationship Some
Monitoring of ECG and pressure during major surgery Is a True Cardiovascular monitoring by ECG Inferred relationship Some
Monitoring of ECG at surgery Is a True Cardiovascular monitoring by ECG Inferred relationship Some
ECG - general Is a False Cardiovascular monitoring by ECG Inferred relationship Some
ECG - improved Is a False Cardiovascular monitoring by ECG Inferred relationship Some
ECG - no new changes Is a False Cardiovascular monitoring by ECG Inferred relationship Some
18 lead ECG monitoring Is a True Cardiovascular monitoring by ECG Inferred relationship Some
3 lead ECG monitoring Is a True Cardiovascular monitoring by ECG Inferred relationship Some
15 lead ECG monitoring Is a True Cardiovascular monitoring by ECG Inferred relationship Some
Continuous ECG monitoring Is a True Cardiovascular monitoring by ECG Inferred relationship Some
12 lead ECG Is a False Cardiovascular monitoring by ECG Inferred relationship Some
ECG - general - NOS Is a False Cardiovascular monitoring by ECG Inferred relationship Some
Electrocardiography NOS Is a False Cardiovascular monitoring by ECG Inferred relationship Some
Apexcardiography Is a True Cardiovascular monitoring by ECG Inferred relationship Some
Measurement of microvolt T wave alternans for ventricular arrhythmia assessment Is a True Cardiovascular monitoring by ECG Inferred relationship Some
Standard ECG Is a False Cardiovascular monitoring by ECG Inferred relationship Some
Ambulatory ECG Is a True Cardiovascular monitoring by ECG Inferred relationship Some
Gated single photon emission computed tomography of myocardium using technetium (99m-Tc) sestamibi Is a True Cardiovascular monitoring by ECG Inferred relationship Some

Reference Sets

Royal Australasian College of Surgeons MALT surgical procedure reference set

Queensland allied health assessment reference set

Procedure foundation reference set

Back to Start