450821005: Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure)


Status: current, Primitive. Date: 31-Jul 2012. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2917013017 Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) en Fully specified name Active Case insensitive SNOMED CT core
2917046011 Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance en Synonym Active Case insensitive SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance Is a Fluoroscopic guidance true Inferred relationship Some
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance Method Fluoroscopic imaging - action false Inferred relationship Some 3
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance Has intent Guidance intent false Inferred relationship Some 3
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance Is a Automatic defibrillator procedure true Inferred relationship Some
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance Is a Replacement of device true Inferred relationship Some
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance Is a Removal of cardiac pacemaker true Inferred relationship Some
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance Method Replacement - action false Inferred relationship Some 2
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance Direct device Pacemaker pulse generator false Inferred relationship Some 2
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance Indirect device Implantable defibrillator false Inferred relationship Some 2
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance Method Replacement - action true Inferred relationship Some 2
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance Method Fluoroscopic imaging - action true Inferred relationship Some 3
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance Direct device Pacemaker pulse generator true Inferred relationship Some 2
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance Has intent Guidance intent true Inferred relationship Some 3
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance Indirect device Implantable defibrillator true Inferred relationship Some 2

Inbound Relationships Type Active Source Characteristic Refinability Group

Reference Sets

Procedure foundation reference set

Imaging procedure reference set

Back to Start