FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.24  |  FHIR Version n/a  User: [n/a]

443577005: Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure)


Status: current, Defined. Date: 30-Sep 2022. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2212991000168112 Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum en Synonym Active Case insensitive SNOMED Clinical Terms Australian extension
4008535012 Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) en Fully specified name Active Case insensitive SNOMED CT core
4008536013 Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast en Synonym Active Case insensitive SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Using substance Contrast media true Inferred relationship Some 1
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Is a Intracranial aneurysm operation true Inferred relationship Some
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Method Surgical insertion - action true Inferred relationship Some 2
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Direct device Vascular stent true Inferred relationship Some 2
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Is a Placement of stent false Inferred relationship Some
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Is a Insertion of stent using fluoroscopic guidance false Inferred relationship Some
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Is a Head angiography false Inferred relationship Some
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Is a Fluoroscopic angiography with contrast false Inferred relationship Some
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Is a Fluoroscopy of head false Inferred relationship Some
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Is a Implantation of soft tissue false Inferred relationship Some
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Is a Intracranial procedure false Inferred relationship Some
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Is a Implantation to cardiovascular system false Inferred relationship Some
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Has intent Guidance intent false Inferred relationship Some 1
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Method Fluoroscopic imaging - action false Inferred relationship Some 1
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Access Percutaneous approach false Inferred relationship Some 2
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Method Insertion - action false Inferred relationship Some 2
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Direct device Stent false Inferred relationship Some 2
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Indirect morphology Aneurysm false Inferred relationship Some 2
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Procedure site - Direct Intracranial vascular structure false Inferred relationship Some 1
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Procedure site - Indirect Intracranial vascular structure false Inferred relationship Some 2
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Procedure site - Direct Intracranial vascular structure true Inferred relationship Some 1
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Method Fluoroscopic imaging - action true Inferred relationship Some 1
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Method Insertion - action false Inferred relationship Some 2
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Procedure site - Indirect Intracranial vascular structure true Inferred relationship Some 2
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Indirect morphology Aneurysm true Inferred relationship Some 2
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Access Percutaneous approach true Inferred relationship Some 2
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Direct device Stent false Inferred relationship Some 2
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Has intent Guidance intent true Inferred relationship Some 1
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Is a Procedure on central nervous system false Inferred relationship Some
Fluoroscopy guided percutaneous insertion of stent into aneurysm of cerebrum Is a Fluoroscopy guided insertion of stent into intracranial vascular structure with contrast true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

Reference Sets

Procedure foundation reference set

Imaging procedure reference set

Back to Start