FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.8.2  |  FHIR Version n/a  User: [n/a]

442096005: Measurement finding outside reference range (finding)


Status: current, Defined. Date: 31-Jul 2009. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2818440011 Measurement finding outside reference range en Synonym Active Case insensitive SNOMED CT core
2818441010 Measurement finding outside reference range (finding) en Fully specified name Active Case insensitive SNOMED CT core


1764 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Measurement finding outside reference range Is a Measurement finding true Inferred relationship Some
Measurement finding outside reference range Interprets Measurement false Inferred relationship Some 1
Measurement finding outside reference range Has interpretation Outside reference range false Inferred relationship Some 1
Measurement finding outside reference range Has interpretation Outside reference range true Inferred relationship Some 1
Measurement finding outside reference range Interprets Measurement true Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group
Renal function tests abnormal Is a True Measurement finding outside reference range Inferred relationship Some
Blood gases abnormal Is a True Measurement finding outside reference range Inferred relationship Some
Cerebrospinal fluid chloride outside reference range Is a False Measurement finding outside reference range Inferred relationship Some
Luteinising hormone level outside reference range Is a True Measurement finding outside reference range Inferred relationship Some
Blood magnesium abnormal Is a True Measurement finding outside reference range Inferred relationship Some
Serum total protein abnormal Is a True Measurement finding outside reference range Inferred relationship Some
Fetoplacental hormones abnormal Is a True Measurement finding outside reference range Inferred relationship Some
Mycoplasma titres abnormal Is a True Measurement finding outside reference range Inferred relationship Some
Abnormal enzyme level in specimen from respiratory organ and thorax Is a False Measurement finding outside reference range Inferred relationship Some
Serum thyroxine level outside reference range Is a False Measurement finding outside reference range Inferred relationship Some
Urine adrenalin level abnormal Is a True Measurement finding outside reference range Inferred relationship Some
Serum aspartate aminotransferase level outside reference range Is a False Measurement finding outside reference range Inferred relationship Some
White blood cell count abnormal Is a False Measurement finding outside reference range Inferred relationship Some
Metabolic function abnormal Is a True Measurement finding outside reference range Inferred relationship Some
Pituitary function test abnormal Is a True Measurement finding outside reference range Inferred relationship Some
Measurement finding above reference range Is a True Measurement finding outside reference range Inferred relationship Some
Abnorm result function stud of other organs and systems Is a False Measurement finding outside reference range Inferred relationship Some
Abn level of other drug,medic+biological subst male organ Is a False Measurement finding outside reference range Inferred relationship Some
Abn level of subst chiefly non-medicinal from digest organ Is a False Measurement finding outside reference range Inferred relationship Some
Abn levels substances chief non-medicinal source fem genital Is a False Measurement finding outside reference range Inferred relationship Some
Abnorm enzyme level findings in specimens from other organs Is a False Measurement finding outside reference range Inferred relationship Some
Abnorm level other drugs,medic+biolog subst female genit org Is a False Measurement finding outside reference range Inferred relationship Some
Abnorm levels oth drugs,medic+biological substances in CSF Is a False Measurement finding outside reference range Inferred relationship Some
Abnorm levels oth drugs,medicaments+substances other organs Is a False Measurement finding outside reference range Inferred relationship Some
Abnorm levels subst chiefly non-med specimens resp/thorax Is a False Measurement finding outside reference range Inferred relationship Some
Abnorm levels substances non-med source in spec other organs Is a False Measurement finding outside reference range Inferred relationship Some
Unspec abn finding spec from respiratory organs and thorax Is a False Measurement finding outside reference range Inferred relationship Some
Red blood cell count outside reference range Is a False Measurement finding outside reference range Inferred relationship Some
Blood pH abnormal Is a False Measurement finding outside reference range Inferred relationship Some
Abnormal urine levels subst chiefly non-medicinal sources Is a False Measurement finding outside reference range Inferred relationship Some
Abnormal iron profile Is a True Measurement finding outside reference range Inferred relationship Some
Abnormal blood cell count Is a True Measurement finding outside reference range Inferred relationship Some

Start Page 2 of 2


Reference Sets

Australian emergency department reference set

Clinical finding foundation reference set

Problem/Diagnosis reference set

Back to Start