Status: current, Primitive. Date: 31-Jan 2007. Module: SNOMED CT core
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
2641506013 | Maintenance of temporary cardiac pacemaker settings (procedure) | en | Fully specified name | Active | Case insensitive | SNOMED CT core |
2645608012 | Maintenance of temporary cardiac pacemaker settings | en | Synonym | Active | Case insensitive | SNOMED CT core |
2649339012 | Temporary cardiac pacemaker settings care | en | Synonym | Active | Case insensitive | SNOMED CT core |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Maintenance of temporary cardiac pacemaker settings | Is a | Maintenance of temporary cardiac pacemaker system | true | Inferred relationship | Some | ||
Maintenance of temporary cardiac pacemaker settings | Procedure device | Cardiac pacemaker | false | Inferred relationship | Some | 1 | |
Maintenance of temporary cardiac pacemaker settings | Procedure site - Indirect | Structure of heart | false | Inferred relationship | Some | 1 | |
Maintenance of temporary cardiac pacemaker settings | Direct device | Temporary cardiac pacemaker, device | false | Inferred relationship | Some | 1 | |
Maintenance of temporary cardiac pacemaker settings | Method | Maintenance - action | false | Inferred relationship | Some | 1 | |
Maintenance of temporary cardiac pacemaker settings | Procedure device | Temporary cardiac pacemaker, device | false | Inferred relationship | Some | 2 | |
Maintenance of temporary cardiac pacemaker settings | Procedure site - Indirect | Structure of heart | false | Inferred relationship | Some | 2 | |
Maintenance of temporary cardiac pacemaker settings | Direct device | Cardiac implant | false | Inferred relationship | Some | 2 | |
Maintenance of temporary cardiac pacemaker settings | Procedure site - Indirect | Structure of heart | false | Inferred relationship | Some | 2 | |
Maintenance of temporary cardiac pacemaker settings | Procedure site - Indirect | Structure of heart | true | Inferred relationship | Some | 2 | |
Maintenance of temporary cardiac pacemaker settings | Procedure device | Temporary cardiac pacemaker, device | true | Inferred relationship | Some | 2 | |
Maintenance of temporary cardiac pacemaker settings | Method | Maintenance - action | true | Inferred relationship | Some | 1 | |
Maintenance of temporary cardiac pacemaker settings | Direct device | Temporary cardiac pacemaker, device | true | Inferred relationship | Some | 1 |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
Reference Sets
Royal Australasian College of Surgeons MALT surgical procedure reference set
Procedure foundation reference set