Status: current, Primitive. Date: 31-Jul 2002. Module: SNOMED CT core
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
1196668014 | Filtering operation on eye (procedure) | en | Fully specified name | Active | Case insensitive | SNOMED CT core |
1210032017 | Filtering operation on eye | en | Synonym | Active | Case insensitive | SNOMED CT core |
2475016019 | Fistulisation of sclera | en | Synonym | Active | Case insensitive | SNOMED CT core |
2475017011 | Scleral fistulising procedure | en | Synonym | Active | Case insensitive | SNOMED CT core |
2475226018 | Scleral fistulizing procedure | en | Synonym | Active | Case insensitive | SNOMED CT core |
2475227010 | Fistulization of sclera | en | Synonym | Active | Case insensitive | SNOMED CT core |
2476699016 | Glaucoma drainage surgery | en | Synonym | Active | Case insensitive | SNOMED CT core |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Filtering operation on eye | Is a | Surgical procedure on eye proper | true | Inferred relationship | Some | ||
Filtering operation on eye | Method | Surgical action | false | Inferred relationship | Some | 1 | |
Filtering operation on eye | Procedure site | Eye structure | false | Inferred relationship | Some | 1 | |
Filtering operation on eye | Method | Surgical action | true | Inferred relationship | Some | 1 | |
Filtering operation on eye | Procedure site | Eye structure | true | Inferred relationship | Some | 1 |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
Surgical construction of filtration bleb | Is a | True | Filtering operation on eye | Inferred relationship | Some | |
Disorder due to insertion of glaucoma drainage device | Due to | True | Filtering operation on eye | Inferred relationship | Some | 3 |
Trabeculectomy ab externo | Is a | False | Filtering operation on eye | Inferred relationship | Some | |
Scleral fistulising procedure | Is a | False | Filtering operation on eye | Inferred relationship | Some | |
Fistulisation of sclera by trephination | Is a | False | Filtering operation on eye | Inferred relationship | Some | |
Iridectomy with scleral fistulisation | Is a | True | Filtering operation on eye | Inferred relationship | Some | |
Postoperative revision of scleral fistulisation procedure | Is a | False | Filtering operation on eye | Inferred relationship | Some | |
Disorder due to insertion of glaucoma drainage device | Associated with | False | Filtering operation on eye | Inferred relationship | Some | 3 |
Reference Sets
Procedure foundation reference set