FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

312243002: Cesium 137 brachytherapy remote afterloading (procedure)


Status: current, Primitive. Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
455923013 Cesium 137 brachytherapy remote afterloading en Synonym Active Case insensitive SNOMED CT core
455924019 Caesium 137 brachytherapy remote afterloading en Synonym Active Case insensitive SNOMED CT core
708894014 Cesium 137 brachytherapy remote afterloading (procedure) en Fully specified name Active Case insensitive SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Caesium 137 brachytherapy remote afterloading Using energy Radiation true Inferred relationship Some 2
Caesium 137 brachytherapy remote afterloading Is a Caesium 137 brachytherapy true Inferred relationship Some
Caesium 137 brachytherapy remote afterloading Has intent Therapeutic true Inferred relationship Some 2
Caesium 137 brachytherapy remote afterloading Method Radionuclide therapy - action false Inferred relationship Some 1
Caesium 137 brachytherapy remote afterloading Using energy Ionising radiation false Inferred relationship Some 1
Caesium 137 brachytherapy remote afterloading Method Brachytherapy - action false Inferred relationship Some 1
Caesium 137 brachytherapy remote afterloading Using substance Radioactive isotope false Inferred relationship Some 1
Caesium 137 brachytherapy remote afterloading Method Brachytherapy - action true Inferred relationship Some 1
Caesium 137 brachytherapy remote afterloading Using substance Radioactive isotope false Inferred relationship Some 1
Caesium 137 brachytherapy remote afterloading Using substance Radioactive isotope false Inferred relationship Some 2
Caesium 137 brachytherapy remote afterloading Method Brachytherapy - action false Inferred relationship Some 1
Caesium 137 brachytherapy remote afterloading Method Action false Inferred relationship Some
Caesium 137 brachytherapy remote afterloading Using Radioactivity false Inferred relationship Some
Caesium 137 brachytherapy remote afterloading Using Ionising radiation false Inferred relationship Some 1
Caesium 137 brachytherapy remote afterloading Method Radioactive destruction false Inferred relationship Some 2
Caesium 137 brachytherapy remote afterloading Is a Procedure categorised by device involved false Inferred relationship Some
Caesium 137 brachytherapy remote afterloading Using device Remote-afterloading brachytherapy system true Inferred relationship Some 1
Caesium 137 brachytherapy remote afterloading Using substance Cesium-137 true Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group
Curietron brachytherapy Is a False Caesium 137 brachytherapy remote afterloading Inferred relationship Some

Reference Sets

Procedure foundation reference set

Back to Start