Status: current, Primitive. Date: 31-Jan 2002. Module: SNOMED CT core
Descriptions:
| Id | Description | Lang | Type | Status | Case? | Module |
| 423871013 | Removal of intracranial electrodes with synchronous replacement | en | Synonym | Active | Case insensitive | SNOMED CT core |
| 678942017 | Removal of intracranial electrodes with synchronous replacement (procedure) | en | Fully specified name | Active | Case insensitive | SNOMED CT core |
| Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
| Removal of intracranial electrodes with synchronous replacement | Is a | Neurostimulation of brain tissue | false | Inferred relationship | Some | ||
| Removal of intracranial electrodes with synchronous replacement | Procedure site | Brain structure | false | Inferred relationship | Some | 2 | |
| Removal of intracranial electrodes with synchronous replacement | Using | Neurostimulation device | false | Inferred relationship | Some | ||
| Removal of intracranial electrodes with synchronous replacement | Is a | Removal of intracranial electrodes | true | Inferred relationship | Some | ||
| Removal of intracranial electrodes with synchronous replacement | Is a | Replacement of device | true | Inferred relationship | Some | ||
| Removal of intracranial electrodes with synchronous replacement | Method | Replacement - action | false | Inferred relationship | Some | 1 | |
| Removal of intracranial electrodes with synchronous replacement | Procedure site - Indirect | Brain tissue structure | false | Inferred relationship | Some | 1 | |
| Removal of intracranial electrodes with synchronous replacement | Direct device | Electrode | false | Inferred relationship | Some | 1 | |
| Removal of intracranial electrodes with synchronous replacement | Method | Replacement - action | true | Inferred relationship | Some | 1 | |
| Removal of intracranial electrodes with synchronous replacement | Procedure site - Indirect | Brain tissue structure | true | Inferred relationship | Some | 1 | |
| Removal of intracranial electrodes with synchronous replacement | Direct device | Electrode | true | Inferred relationship | Some | 1 | |
| Removal of intracranial electrodes with synchronous replacement | Procedure site | Brain tissue structure | false | Inferred relationship | Some | 1 | |
| Removal of intracranial electrodes with synchronous replacement | Method | Surgical action | false | Inferred relationship | Some | 1 | |
| Removal of intracranial electrodes with synchronous replacement | Direct device | Neurostimulator electrode | false | Inferred relationship | Some |
| Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
| Replacement of intracranial electrodes by incision or trephination | Is a | True | Removal of intracranial electrodes with synchronous replacement | Inferred relationship | Some |
Reference Sets
Royal Australasian College of Surgeons MALT surgical procedure reference set
Procedure foundation reference set