FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.24  |  FHIR Version n/a  User: [n/a]

195101003: Wandering atrial pacemaker (finding)


Status: current, Primitive. Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
1418361000168117 ECG: wandering atrial pacemaker en Synonym Active Case sensitive SNOMED Clinical Terms Australian extension
1418371000168111 Electrocardiogram: wandering atrial pacemaker en Synonym Active Case insensitive SNOMED Clinical Terms Australian extension
300164012 Wandering atrial pacemaker en Synonym Active Case insensitive SNOMED CT core
579158011 Wandering atrial pacemaker (finding) en Fully specified name Active Case insensitive SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
ECG: wandering atrial pacemaker Finding site Cardiovascular system subdivision false Inferred relationship Some
ECG: wandering atrial pacemaker Interprets Cardiovascular function false Inferred relationship Some
ECG: wandering atrial pacemaker Is a Viscus structure finding false Inferred relationship Some
ECG: wandering atrial pacemaker Finding method Procedure false Inferred relationship Some
ECG: wandering atrial pacemaker Is a Abnormal ECG true Inferred relationship Some
ECG: wandering atrial pacemaker Is a Cardiac finding true Inferred relationship Some
ECG: wandering atrial pacemaker Interprets ECG procedure false Inferred relationship Some 1
ECG: wandering atrial pacemaker Has interpretation Abnormal false Inferred relationship Some 1
ECG: wandering atrial pacemaker Has interpretation Abnormal true Inferred relationship Some 1
ECG: wandering atrial pacemaker Interprets ECG procedure true Inferred relationship Some 1
ECG: wandering atrial pacemaker Finding site Cardiac conducting system structure true Inferred relationship Some 2
ECG: wandering atrial pacemaker Interprets General ECG appearance false Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group
Wandering pacemaker Has definitional manifestation False ECG: wandering atrial pacemaker Inferred relationship Some
Wandering pacemaker Has definitional manifestation False ECG: wandering atrial pacemaker Inferred relationship Some

Reference Sets

Australian emergency department reference set

Queensland allied health clinical finding reference set

Clinical finding foundation reference set

Cardiovascular finding reference set

Problem/Diagnosis reference set

Back to Start