FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

175011002: Saphenous vein graft replacement of four or more coronary arteries (procedure)


    Status: retired, Primitive. Date: 31-Jan 2018. Module: SNOMED CT core

    Descriptions:

    Id Description Lang Type Status Case? Module
    271077019 Saphenous vein graft replacement of four or more coronary arteries en Synonym Active Case insensitive SNOMED CT core
    557509010 Saphenous vein graft replacement of four or more coronary arteries (procedure) en Fully specified name Active Case insensitive SNOMED CT core


    0 descendants.

    Expanded Value Set


    Outbound Relationships Type Target Active Characteristic Refinability Group Values
    Saphenous vein graft replacement of four or more coronary arteries Is a Aortocoronary artery bypass graft with saphenous vein graft false Inferred relationship Some
    Saphenous vein graft replacement of four or more coronary arteries Method Repair - action false Inferred relationship Some 1
    Saphenous vein graft replacement of four or more coronary arteries Method Repair - action false Inferred relationship Some 2
    Saphenous vein graft replacement of four or more coronary arteries Method Bypass - action false Inferred relationship Some 1
    Saphenous vein graft replacement of four or more coronary arteries Procedure site Coronary artery structure false Inferred relationship Some 1
    Saphenous vein graft replacement of four or more coronary arteries Procedure site Blood vessel structure false Inferred relationship Some 2
    Saphenous vein graft replacement of four or more coronary arteries Procedure site Coronary artery structure false Inferred relationship Some 2
    Saphenous vein graft replacement of four or more coronary arteries Method Revascularisation - action false Inferred relationship Some 2
    Saphenous vein graft replacement of four or more coronary arteries Procedure site Coronary artery structure false Inferred relationship Some 1
    Saphenous vein graft replacement of four or more coronary arteries Procedure site Coronary artery structure false Inferred relationship Some 2
    Saphenous vein graft replacement of four or more coronary arteries Procedure site Coronary artery structure false Inferred relationship Some 2
    Saphenous vein graft replacement of four or more coronary arteries Procedure site Coronary artery structure false Inferred relationship Some 1
    Saphenous vein graft replacement of four or more coronary arteries Procedure site Coronary artery structure false Inferred relationship Some 1
    Saphenous vein graft replacement of four or more coronary arteries Procedure site Coronary artery structure false Inferred relationship Some 2
    Saphenous vein graft replacement of four or more coronary arteries Procedure site Coronary artery structure false Inferred relationship Some 1
    Saphenous vein graft replacement of four or more coronary arteries Procedure site Coronary artery structure false Inferred relationship Some 2
    Saphenous vein graft replacement of four or more coronary arteries Procedure site - Direct Coronary artery structure false Inferred relationship Some 1
    Saphenous vein graft replacement of four or more coronary arteries Procedure site - Direct Aortic structure false Inferred relationship Some 2
    Saphenous vein graft replacement of four or more coronary arteries Method Bypass - action false Inferred relationship Some 1
    Saphenous vein graft replacement of four or more coronary arteries Method Bypass - action false Inferred relationship Some 2
    Saphenous vein graft replacement of four or more coronary arteries Method Bypass - action false Inferred relationship Some 2
    Saphenous vein graft replacement of four or more coronary arteries Procedure site - Direct Coronary artery structure false Inferred relationship Some 2
    Saphenous vein graft replacement of four or more coronary arteries Method Bypass - action false Inferred relationship Some 1
    Saphenous vein graft replacement of four or more coronary arteries Procedure site - Direct Aortic structure false Inferred relationship Some 1
    Saphenous vein graft replacement of four or more coronary arteries Using substance Vein graft material false Inferred relationship Some 1
    Saphenous vein graft replacement of four or more coronary arteries Using substance Vein graft material false Inferred relationship Some 2
    Saphenous vein graft replacement of four or more coronary arteries Procedure site Arterial graft false Inferred relationship Some
    Saphenous vein graft replacement of four or more coronary arteries Method Anastomosis - action false Inferred relationship Some
    Saphenous vein graft replacement of four or more coronary arteries Procedure site Venous structure false Inferred relationship Some
    Saphenous vein graft replacement of four or more coronary arteries Method Construction - action false Inferred relationship Some
    Saphenous vein graft replacement of four or more coronary arteries Procedure site Aortic structure false Inferred relationship Some 1
    Saphenous vein graft replacement of four or more coronary arteries Method Surgical repair - action false Inferred relationship Some

    Inbound Relationships Type Active Source Characteristic Refinability Group
    Saphenous vein graft replacement of five coronary arteries Is a False Saphenous vein graft replacement of four or more coronary arteries Inferred relationship Some
    Saphenous vein graft replacement of four coronary arteries Is a False Saphenous vein graft replacement of four or more coronary arteries Inferred relationship Some

    Reference Sets

    Concept inactivation indicator reference set

    REPLACED BY association reference set

    Back to Start